Our study was conducted to demonstrate the primary factors involved in fires which result from an automobile's electrical wire harness system with fuses. In our experiments we used modeled automobile wire harnesses to study the processes of ignition and the resultant fires. Current was passed through blade type fuses to a portion of the harness and was intermittently short-circuited by a grounded metal plate. The nominal current ratings of the fuses we used were lower than or equal to 30 amperes [A], and the operating current was 30A at 12 Volts. Current flowed to the harness specimens through a DC power source.
We found that electrical tracking with scintillation, caused by a weak electric flow through carbonized wire insulation, rarely generated flames in the wire harnesses without blowing the fuse. Ignition was never observed on the insulation near the areas shorted by the arc and/or overloaded currents going to the wire elements.
The ignition process with tracking may be one of the mechanisms involved in igniting fires in a vehicle's electric wire harness.

SAE MOBILUS

Subscribers can view annotate, and download all of SAE's content. Learn More »

Access SAE MOBILUS »

Members save up to 16% off list price.
Login to see discount.
Special Offer: Download multiple Technical Papers each year? TechSelect is a cost-effective subscription option to select and download 12-100 full-text Technical Papers per year. Find more information here.
We also recommend:
STANDARD

Brake Insulator Damping Measurement Procedure

J3001_201604

View Details

TECHNICAL PAPER

Applying Spin Welding Technology to Replace Current Quick Connect Installation Processes

2006-01-0133

View Details

TECHNICAL PAPER

New Low Cost High Performance Materials for Automotive Connectors and Light Sockets

2002-01-1322

View Details

X