Technical Paper

Development of Closed-Loop Robust Control System for Diesel Engines - Combustion Monitoring by Crank Angular Velocity Analysis and its Applications -

2012-04-16
2012-01-1157
Closed-loop robust control system that can monitor combustion state and control it into optimal state using crank angular velocity analysis was established. The system can be constructed without any change of the current hardware. It can avoid engine stall, deterioration of drivability and white smoke emission by misfire after filling low cetane fuels. This study was attempted to grasp the frequency characteristics of crank angular velocity both normal combustion and misfire with FFT (Fast Fourier Transform) and Wavelet Transform. FFT used for frequency analysis is generic method to acquire the frequency characteristics of steady oscillation, however is unsuitable for acquiring the frequency characteristics of transient oscillation. Therefore authors adopted Wavelet Transform and succeeded in grasping the phenomenon in misfiring in time sequential.
Technical Paper

Study on Ignition Timing Control for Diesel Engines Using In-Cylinder Pressure Sensor

2006-04-03
2006-01-0180
As technologies for simultaneously maintaining the current high thermal efficiency of diesel engines and reducing particulate matter (PM) and nitrogen oxide (NOX) emissions, many new combustion concepts have been proposed, including premixed charge compression ignition (PCCI) and low-temperature combustion[1]. However, it is well known that since such new combustion techniques precisely control combustion temperatures and local air-fuel ratios by varying the amount of air, the exhaust gas recirculation (EGR) ratio and the fuel injection timing, they have the issues of being less stable than conventional combustion techniques and of performance that is subject to variance in the fuel and driving conditions. This study concerns a system that addresses these issues by detecting the ignition timing with in-cylinder pressure sensors and by controlling the fuel injection timing and the amount of EGR for optimum combustion onboard.
Technical Paper

Study on Combustion Monitoring System for Formula One Engines Using Ionic Current Measurement

2004-06-08
2004-01-1921
Formula One engines, which are the pursuit of the ultimate in performance, tend to be comparatively vulnerable to durability issues. These engines sometimes run under a state of unstable combustion as compensation for improved fuel economy. To cope with these issues, there have been strong demands in the racing field for a technology that will allow constant monitoring and prompt action to be carried out on system malfunctions and failures, as well as unstable combustion. The research program described in this paper deals with an onboard technology for monitoring combustion under all the operational conditions using ionic current measurement. The technology will possibly be applied to engine management and car-to-pit communications via telemetering. The scope of the control it offers includes; detection of misfire and hesitation, detection and management of detonation, and management of lean-burn combustion.
Technical Paper

Study on Engine Management System Using In-cylinder Pressure Sensor Integrated with Spark Plug

2004-03-08
2004-01-0519
There has been strong public demand for reduced hazardous exhaust gas emissions and improved fuel economy for automobile engines. In recent years, a number of innovative solutions that lead to a reduction in fuel consumption rate have been developed, including in-cylinder direct injection and lean burn combustion technologies, as well as an engine utilizing a large volume of exhaust gas recirculation (EGR). Furthermore, a homogeneous charge compression ignition (HCCI) engine is under development for actual application. However, one of the issues common to these technologies is less stable combustion, which causes difficulty in engine management. Additionally, it is now mandatory to provide an onboard diagnosis (OBD) system. This requires manufacturers to develop a technology that allows onboard monitoring and control of the combustion state. This paper reports on an innovative combustion diagnostic method using an in-cylinder pressure sensor.
Technical Paper

Development of Extruded Electrically Heated Catalyst System for ULEV Standards

1997-02-24
971031
Into the early-part of the next century, automotive emission standards are becoming stricter around the world. The electrically-heated catalyst (EHC) is well known as an effective technology for the reduction of cold-start hydrocarbon emissions without a significant increase in back pressure. Our extruded, alternator powered EHC (APEHC) manufactured with a unique canning method and equipped with a reliable, water proof electrode has demonstrated excellent durability and reliability, as stated in our previous SAE paper (#960340). The APEHC system discussed in this paper has achieved the Ultra-Low-Emission Vehicle (ULEV) standards, after 100,000 miles of fleet testing, without any failure. This is the final milestone in addressing the EHC as a realistic-production technology for ULEV. With the ability to meet ULEV/Stage III emission targets without a significant increase in back pressure, the EHC will be applied to an especially high performance vehicle with a large displacement engine.
Technical Paper

Study on Conformity Technology with ULEV Using EHC System

1996-02-01
960342
An electrically heated catalyst (EHC) and an electric pump driven secondary air supply were employed to heat and energize the catalyst immediately after starting the engine. This measure made it possible for a high performance in-line four-cylinder engine with an exhaust system layout of 4-2-1 to meet the Ultra Low Emissions Vehicle (ULEV) category of the Californian Air Resource Board (CARB).
Technical Paper

Development of Engine Roughness Tester

1996-02-01
960617
We have developed a new engine roughness tester which is capable of monitoring the spark plug voltage and crankshaft speed fluctuation as well as detecting the misfire of the SI internal combustion engine. In order to detect misfire, the newly developed “spark plug voltage analysis method” is combined with the conventional “crankshaft speed fluctuation method”. It is capable of logging ordinary data, determining the waveform for a detection / misfire
Technical Paper

Flame Ion Density Measurement Using Spark Plug Voltage Analysis

1993-03-01
930462
The corelation between flame ion density and engine operating condition, such as air fuel ratio mixture and cylinder pressure peak value, etc., is commonly known. However, due to the difficulty of ion probe installation in the engine and the interruption of the high voltage ignition spark, the ionization current method is not optimally utilized. This paper presents the Spark Plug Voltage-ion method which requires a minor modification to the ignition system and will indirectly detect flame ion density. The voltage sensor is a voltage divider by capacitance which measures the spark plug voltage. The resulting behavior of the voltage wave form is noteworthy. After spark discharge, the stored residual charge of the spark plug starts to discharge by ion in a flame. Therefore, ion density in a flame is detected by the decay time of spark plug voltage.
Technical Paper

Spark Plug Voltage Analysis for Monitoring Combustion in an Internal Combustion Engine

1993-03-01
930461
The idea to monitor the combustion in an internal combustion engine and using the obtained data to control combustion in the engine has been around for some time now. There are two well-known methods, although in the capacity of lab experiments, which had been developed under this principle. One features the analysis of combustion pressure and the other features the analysis of ionic currents detected in the combustion gas. Although highly precise analysis can be achieved by the former, there are problems in the installation of sensors for detecting combustion pressure, also in the durability and cost of such sensors. As for the latter, there are also problems in installing sensors for detecting the ionic currents and the reliability of obtained data from such sensors is still questionable.