Technical Paper
Cooling Effects of Air-Cooled Finned Cylinder Utilizing Contracted Flow
2009-04-20
2009-01-0176
In air-cooled motorbike and stationary engines, waste heat dissipates from the cylinder through the cooling fins to the cooling air. In these engines, the cooling air flow follows the cylinder surface at the front of the cylinder, but separates at the rear, reducing cooling. To increase the distance over which the air flow follows the cylinder surface before it separates from the cylinder, and so to increase cooling at the rear, we experimented with cylinders utilizing contracted flow between fins. These cylinders have fins with different thickness at the front and the rear, so as to contract the air flow around the cylinder. We produced and tested three experimental cylinders with various lengths of contracted fins (tapered fins), in a wind tunnel at air velocities between 20 and 60km/h. We measured the temperature inside the cylinder over time to determine the heat release from the cylinder.