Standard

Instrumentation for Impact Test, Part 1 - Electronic Instrumentation

2023-02-06
WIP
J211/1
This SAE Recommended Practice outlines a series of performance recommendations, which concern the whole data channel. These recommendations are not subject to any variation and all of them shall be adhered to by any agency conducting tests to this practice. However, the method of demonstrating compliance with the recommendations is flexible and can be adapted to suit the needs of the particular equipment the agency is using.It is not intended that each recommendation be taken in a literal sense, as necessitating a single test to demonstrate that the recommendation is met. Rather, it is intended that any agency proposing to conduct tests to this practice shall be able to demonstrate that if such a single test could be and were carried out, then their equipment would meet the recommendations.
Standard

Instrumentation for Impact Test Part 1 - Electronic Instrumentation

2022-08-19
CURRENT
J211/1_202208
This SAE Recommended Practice outlines a series of performance recommendations, which concern the whole data channel. These recommendations are not subject to any variation and all of them shall be adhered to by any agency conducting tests to this practice. However, the method of demonstrating compliance with the recommendations is flexible and can be adapted to suit the needs of the particular equipment the agency is using. It is not intended that each recommendation be taken in a literal sense, as necessitating a single test to demonstrate that the recommendation is met. Rather, it is intended that any agency proposing to conduct tests to this practice shall be able to demonstrate that if such a single test could be and were carried out, then their equipment would meet the recommendations. This demonstration shall be undertaken on the basis of reasonable deductions from evidence in their possession, such as the results of partial tests.
Standard

Calculation Guidelines for Impact Testing

2021-10-29
WIP
J1727
This SAE Recommended Practice presents a series of standard calculations and numerical methods for processing safety test instrumentation data that has been acquired during impact tests with instruments installed in ATD’s (crash test dummies), vehicle structures, and laboratory fixtures. The output data from performing these calculations may have applications that include energy analysis, biomechanical analysis, regulation compliance, or other purposes. However, application of the output data from these calculations is outside the scope of this document. It is the intent of this document to present a basic set of calculations that are applicable to test labs that follow the practices set forth by SAE J211-1, SAE J211-2, SAE J2570, and SAE J1733. For the calculations that are described in other sources, the relevant documents are referenced.
Standard

Performance Specifications for Anthropomorphic Test Device Transducers

2019-11-13
CURRENT
J2570_201911
This SAE Recommended Practice defines the minimum performance specifications for sensors used within anthropomorphic test devices (ATDs) when performing impact tests per SAE J211. It is intended that any agency proposing to conduct tests in accordance with SAE J211 shall be able to demonstrate that the transducers they use would meet the performance requirements specified in this document.
Standard

Sign Convention for Vehicle Crash Testing

2018-11-14
CURRENT
J1733_201811
In order to compare test results obtained from different crash test facilities, standardized coordinate systems need to be defined for crash test dummies, vehicle structures, and laboratory fixtures. In addition, recorded polarities for various transducer outputs need to be defined relative to positive directions of the appropriate coordinate systems. This SAE Information Report describes the standardized sign convention and recorded output polarities for various transducers used in crash testing.
Standard

Test Device Head Contact Duration Analysis

2016-07-12
CURRENT
J2052_201607
This methodology can be used for all calculations of HIC, with all test devices having an upper neck triaxial load cell mounted rigidly to the head, and head triaxial accelerometers.
Standard

Calculation Guidelines for Impact Testing

2015-02-03
CURRENT
J1727_201502
This SAE Recommended Practice presents a series of standard calculations and numerical methods for processing safety test instrumentation data that has been acquired during impact tests with instruments installed in ATD’s (crash test dummies), vehicle structures, and laboratory fixtures. The output data from performing these calculations may have applications that include energy analysis, biomechanical analysis, regulation compliance, or other purposes. However, application of the output data from these calculations is outside the scope of this document. It is the intent of this document to present a basic set of calculations that are applicable to test labs that follow the practices set forth by SAE J211-1, SAE J211-2, SAE J2570, and SAE J1733. For the calculations that are described in other sources, the relevant documents are referenced.
Standard

Instrumentation for Impact Test - Part 1 - Electronic Instrumentation

2014-03-31
HISTORICAL
J211/1_201403
This recommended practice outlines a series of performance recommendations, which concern the whole data channel. These recommendations are not subject to any variation and all of them shall be adhered to by any agency conducting tests to this practice. However, the method of demonstrating compliance with the recommendations is flexible and can be adapted to suit the needs of the particular equipment the agency is using. It is not intended that each recommendation be taken in a literal sense, as necessitating a single test to demonstrate that the recommendation is met. Rather, it is intended that any agency proposing to conduct tests to this practice shall be able to demonstrate that if such a single test could be and were carried out, then their equipment would meet the recommendations. This demonstration shall be undertaken on the basis of reasonable deductions from evidence in their possession, such as the results of partial tests.
Standard

Test Device Head Contact Duration Analysis

2011-01-05
HISTORICAL
J2052_201101
This methodology can be used for all calculations of HIC, with all test devices having an upper neck triaxial load cell mounted rigidly to the head, and head triaxial accelerometers.
Standard

Calculation Guidelines for Impact Testing

2010-02-15
HISTORICAL
J1727_201002
The scope was changed to provide focus on the details of performing the included calculations and to remove any inference, implication, or suggestion that this Recommended Practice has the purpose of predicting the risk or probability of injury.
Standard

Performance Specifications for Anthropomorphic Test Device Transducers

2009-08-12
HISTORICAL
J2570_200908
This SAE Information Report defines the minimum performance specifications for accelerometers, load cells, and angular position transducers used within Anthropomorphic Test Devices (ATDs) when performing impact tests per SAE J211, “Instrumentation for Impact Test”. This report does not define methodology and equipment for performing verification tests of the transducers. It is intended that any agency proposing to conduct tests in accordance with SAE J211 shall be able to demonstrate that the transducers they use would meet the performance requirements specified in this document.
Standard

Sign Convention for Vehicle Crash Testing

2007-11-02
HISTORICAL
J1733_200711
In order to compare test results obtained from different crash test facilities, standardized coordinate systems need to be defined for crash test dummies, vehicle structures, and laboratory fixtures. In addition, recorded polarities for various transducer outputs need to be defined relative to positive directions of the appropriate coordinate systems. This SAE Information Report describes the standardized sign convention and recorded output polarities for various transducers used in crash testing.
Standard

Instrumentation for Impact Test—Part 1—Electronic Instrumentation

2007-07-27
HISTORICAL
J211/1_200707
This recommended practice outlines a series of performance recommendations, which concern the whole data channel. These recommendations are not subject to any variation and all of them shall be adhered to by any agency conducting tests to this practice. However, the method of demonstrating compliance with the recommendations is flexible and can be adapted to suit the needs of the particular equipment the agency is using. It is not intended that each recommendation be taken in a literal sense, as necessitating a single test to demonstrate that the recommendation is met. Rather, it is intended that any agency proposing to conduct tests to this practice shall be able to demonstrate that if such a single test could be and were carried out, then their equipment would meet the recommendations. This demonstration shall be undertaken on the basis of reasonable deductions from evidence in their possession, such as the results of partial tests.
Standard

Test Device Head Contact Duration Analysis

2005-12-14
HISTORICAL
J2052_200512
This methodology can be used for all calculations of HIC, with all test devices having an upper neck triaxial load cell mounted rigidly to the head, and head triaxial accelerometers.
Standard

Instrumentation for Impact Test—Part 1—Electronic Instrumentation

2003-12-03
HISTORICAL
J211/1_200312
This recommended practice outlines a series of performance recommendations, which concern the whole data channel. These recommendations are not subject to any variation and all of them shall be adhered to by any agency conducting tests to this practice. However, the method of demonstrating compliance with the recommendations is flexible and can be adapted to suit the needs of the particular equipment the agency is using. It is not intended that each recommendation be taken in a literal sense, as necessitating a single test to demonstrate that the recommendation is met. Rather, it is intended that any agency proposing to conduct tests to this practice shall be able to demonstrate that if such a single test could be and were carried out, then their equipment would meet the recommendations. This demonstration shall be undertaken on the basis of reasonable deductions from evidence in their possession, such as the results of partial tests.
Standard

Performance Specifications for Anthropomorphic Test Device Transducers

2001-09-27
HISTORICAL
J2570_200109
This SAE Information Report defines the minimum performance specifications for accelerometers, load cells, and angular position transducers used within Anthropomorphic Test Devices (ATDs) when performing impact tests per SAE J211, “Instrumentation for Impact Test”. This report does not define methodology and equipment for performing verification tests of the transducers. It is intended that any agency proposing to conduct tests in accordance with SAE J211 should be able to demonstrate that the transducers they use would meet the performance requirements specified in this information report.