Standard

Primary Single Phase Nominal 120 VAC Wiring Distribution Assembly Design—Truck and Bus

2008-01-14
HISTORICAL
J2698_200801
This SAE Recommended Practice covers the design and application of primary on-board wiring distribution system harnessing for surface vehicles. This document is intended for single phase nominal 120 VAC circuits that provide power to truck sleeper cab hotel loads so that they may operate with the main propulsion engine turned off. The power supply comes from alternative sources such as land-based grid power, DC-AC inverters and auxiliary power generators. The circuits may also provide power to improve vehicle performance through charging batteries or operating cold-weather starting aids.
Standard

HEAVY-DUTY CIRCUIT BREAKERS

1996-04-01
HISTORICAL
J1625_199604
This SAE Recommended Practice defines the test conditions, procedures, and performance requirements for circuit breakers in ratings from 50 to 200 A. The document covers externally mounted automatic reset and manually reset types of circuit breakers for low voltage DC operation (typically 50 V or less).
Standard

Heavy-Duty Circuit Breakers

2004-09-13
HISTORICAL
J1625_200409
This SAE Standard defines the test conditions, procedures, and performance requirements for circuit breakers in ratings from 50 to 200 A. This document covers automatic reset, modified reset and manual reset types of circuit breakers for low voltage DC systems (12 V and 24 V).
Standard

Heavy-Duty Circuit Breakers

2013-05-03
CURRENT
J1625_201305
This SAE Recommended Practice defines the test conditions, procedures, and performance requirements for circuit breakers in ratings from 50 to 200 A. The document covers externally mounted automatic reset and manually reset types of circuit breakers for low voltage DC operation (typically 50 V or less).
Standard

Positive Temperature Coefficient Overcurrent Protection Devices (PTCs)

2014-12-03
CURRENT
J2685_201412
This SAE Recommended Practice defines the test conditions, procedures, and performance requirements for PTC (positive temperature coefficient of resistance) overcurrent protection devices. PTCs are typically either polymeric (PPTC) or ceramic (CPTC). It is important to note battery voltages versus powernets/system voltage versus max battery voltages: (12 V/14 V/16 V, 24 V/28 V/32 V, and 36 V/42 V/58 V). All voltages are DC. These devices are typically rated with a maximum operating voltage, which for vehicular systems need to be 16 V (for 12 V batteries), 32 V (for 24 V batteries), and 58 V (for 36 V batteries/42 V powernets). PTC devices are considered to be self-resetting after responding to overcurrent conditions and after such condition has been removed from the affected circuit containing the PTC.
Standard

Positive Temperature Coefficient Overcurrent Protection Devices (PTCs)

2006-05-18
HISTORICAL
J2685_200605
This SAE Recommended Practice defines the test conditions, procedures, and performance requirements for PTC (positive temperature coefficient of resistance) overcurrent protection devices. PTCs are typically either polymeric (PPTC) or ceramic (CPTC). It is important to note battery voltages versus powernets/system voltage versus max battery voltages: (12 V/14 V/16 V, 24 V/28 V/32 V, and 36 V/42 V/58 V). All voltages are DC. These devices are typically rated with a maximum operating voltage, which for vehicular systems need to be 16 V (for 12 V batteries), 32 V (for 24 V batteries), and 58 V (for 36 V batteries/42 V powernets). PTC devices are considered to be self-resetting after responding to overcurrent conditions and after such condition has been removed from the affected circuit containing the PTC.
Standard

Heavy Duty High Speed Datalink Connector

2020-01-08
CURRENT
J2839_202001
This SAE Recommended Practice defines the performance requirements, size and mating interfaces for M12 style 4 and 5 pole Heavy Duty High Speed Datalink connection systems, and applies to both cable-to-cable and cable-to-device connectors.
Standard

Heavy Duty High Speed Datalink Connector

2010-02-18
HISTORICAL
J2839_201002
This SAE Recommended Practice defines the performance requirements, size and mating interfaces for M12 style 4 and 5 pole Heavy Duty High Speed Datalink connection systems, and applies to both cable-to-cable and cable-to-device connectors.
Standard

Heavy Duty High Speed Datalink Connector

2015-07-08
HISTORICAL
J2839_201507
This SAE Recommended Practice defines the performance requirements, size and mating interfaces for M12 style 4 and 5 pole Heavy Duty High Speed Datalink connection systems, and applies to both cable-to-cable and cable-to-device connectors.
Standard

Cable Marking for Circuit Identification in Multi-Voltage Power Distribution Systems

2021-01-13
CURRENT
J3176_202101
This SAE Standard establishes the minimum circuit identification and requirements for Multi-Voltage Power Distribution Systems (MVPDS) for use on trucks and buses. A Multi-Voltage Power Distribution System is one that distributes two or three voltages, up to 60 VDC, to power the controls, instruments, and devices.
Standard

Coiled Electrical Cable—Truck and Bus

2007-06-12
HISTORICAL
J2222_200706
This SAE Standard establishes the minimum performance and endurance requirements for coiled electrical cables used for hookup between trucks, trailers and dollies. The component standards SAE J2394 (replaced SAE J1067) for cable and SAE J560 for connectors must be consulted to determine the complete performance and endurance requirements of the system. Related TMC Recommended Practices may be consulted for information associated with selection, installation and inspection of these coiled electrical cables. This document is intended to set out requirements for the majority of conditions rather than for specialized applications or environments.