Refine Your Search

Search Results

Technical Paper

A Regional Finite Element Model of the Neck for Bilateral Carotid Artery Injury Assessment in Far Side Crash Configuration

2009-06-09
2009-01-2265
Carotid artery injury due to motor vehicle crash has been attributed to direct impact to the neck and stretching of the artery. This study examines the response of a finite element model of the neck and carotid arteries given a farside vehicle impact. This regional carotid artery model was developed using existing material properties and based on a spine model developed by NHTSA. The finite element model was subjected to loading conditions derived from farside PMHS tests conducted at Medical College of Wisconsin. The PMHS tests represented four inboard belt loading conditions of the neck. The belts were located high on the neck, for maximal compression of the vessel, or low on the neck, for maximal excursion of the head. There was a low speed and a high speed test for each of the belt configurations. These boundary conditions were implemented in the model and the response of the carotid was quantified using strain measurements.
Technical Paper

A Multi-Modality Image Data Collection Protocol for Full Body Finite Element Model Development

2009-06-09
2009-01-2261
This study outlines a protocol for image data collection acquired from human volunteers. The data set will serve as the foundation of a consolidated effort to develop the next generation full-body Finite Element Analysis (FEA) models for injury prediction and prevention. The geometry of these models will be based off the anatomy of four individuals meeting extensive prescreening requirements and representing the 5th and 50th percentile female, and the 50th and 95th percentile male. Target values for anthropometry are determined by literature sources. Because of the relative strengths of various modalities commonly in use today in the clinical and engineering worlds, a multi-modality approach is outlined. This approach involves the use of Computed Tomography (CT), upright and closed-bore Magnetic Resonance Imaging (MRI), and external anthropometric measurements.
Technical Paper

Dynamic Biaxial Tissue Properties of Pregnant Porcine Uterine Tissue

2008-11-03
2008-22-0007
Automobile crashes are the largest single cause of death for pregnant females and the leading cause of traumatic fetal injury mortality in the United States. Current research for pregnant occupant safety utilizing computational models is limited by available pregnant tissue data. The purpose of this study is to collect experimental data from biaxial tissue tests on pregnant uterine tissue at a dynamic rate. Experimental tests were completed on pregnant porcine uterus which was chosen as a surrogate for the human pregnant uterus given its similarity and availability. Biaxial dynamic tensile tests were performed using a custom-designed system of linear motors to pull a cruciform-shaped specimen in tension simultaneously with four tissue clamps. The test series included 23 tests with corresponding peak stress and strain measurements of the central region of the specimen where optical markers tracked local displacements.
Technical Paper

The Influence of Arm Position on Thoracic Response in Side Impacts

2008-11-03
2008-22-0016
The purpose of this study was to investigate the influence of arm position on thoracic response and injury severity in side impacts. A total of sixteen non-destructive side impact tests and four destructive side impact tests were preformed using four human male cadavers. Single-axis strain gages were placed on the lateral and posterior regions of ribs three through eight on the impacted side, and the lateral region of ribs three through eight on the non-impacted side. Thoracic rods attached to ribs five, seven, and nine were used to measure lateral rib deflection. For the non-destructive tests, four test conditions with different arm positions were evaluated for each cadaver by performing displacement-controlled, low-energy, lateral impacts, 16 kg at 3 m/s, with a pneumatic impactor. The results of these tests showed that the highest average peak forces, peak rib deflections, and peak rib strains were observed when only the ribs were impacted and lowest when the shoulder was impacted.
Technical Paper

Development and Validation of a Synthetic Eye and Orbit for Estimating the Potential for Globe Rupture Due to Specific Impact Conditions

2007-10-29
2007-22-0016
The Facial and Ocular CountermeasUre Safety (FOCUS) headform is intended to aid safety equipment design in order to reduce the risk of eye and facial injuries. The purpose of this paper is to present a three part study that details the development and validation of the FOCUS synthetic eye and orbit and the corresponding eye injury criteria. The synthetic eye and orbit were designed to simulate the force-deflection response to in-situ dynamic impacts. In part I, the force-deflection response of the eye was determined based on dynamic blunt impact tests with human eyes. These data were used to validate the appropriate material for a biofidelic synthetic eye. In part II, force-deflection corridors developed from ten dynamic in-situ eye impacts were used to validate the design and material selections for the synthetic orbit assembly.
Technical Paper

The Biomechanics of Human Ribs: Material and Structural Properties from Dynamic Tension and Bending Tests

2007-10-29
2007-22-0011
The purpose of this study was to quantify both the tensile material properties and structural response of human ribs in order to determine which variables contribute to regional variation in the strength of human ribs. This was done by performing 94 matched tests on human rib specimens; 46 tension coupon tests, 48 three-point bending tests. Contralateral matched specimens were dissected from anterior and lateral regions of ribs 4 through 7 of six male fresh frozen post mortem human subjects ranging from 42 to 81 years of age. Tension coupons were taken from one side of the thorax, while three-point bending specimens were taken from the opposite side as the tension coupons at corresponding anatomical locations. The results of the tension coupon testing showed that there were no significant differences with respect to region or rib level: ultimate stress (p=0.90; p=0.53), ultimate strain (p=0.49; p=0.86), or modulus (p=0.72; p=0.81).
Technical Paper

Development of a Finite Element-Based Injury Metric for Pulmonary Contusion Part I: Model Development and Validation

2005-11-09
2005-22-0013
Pulmonary contusion is the most commonly identified thoracic soft tissue injury in an automobile crash and after blunt chest trauma and affects 10-17% of all trauma admissions. The mortality associated with pulmonary contusions is significant and is estimated to be 10-25%. Thus, there is a need to develop a finite element model based injury metric for pulmonary contusion for the purpose of predicting outcome. This will enable current and future finite element models of the lung to incorporate an understanding of how stress and strain may be related to contusion injuries. This study utilizes 14 impacts onto male Sprague-Dawley rats. In 5 of these tests, a calibrated weight (46 g) is dropped from a height of 44 cm directly onto the lungs of intubated, anesthetized rats in situ. Contused volume is estimated from MicroPET scans of the lung and normalized on the basis of liver uptake of 18F-FDG.
Technical Paper

Material Properties of Human Rib Cortical Bone from Dynamic Tension Coupon Testing

2005-11-09
2005-22-0010
The purpose of this study was to develop material properties of human rib cortical bone using dynamic tension coupon testing. This study presents 117 human rib cortical bone coupon tests from six cadavers, three male and three female, ranging in age from 18 to 67 years old. The rib sections were taken from the anterior, lateral, and posterior regions on ribs 1 through 12 of each cadaver's rib cage. The cortical bone was isolated from each rib section with a low speed diamond saw, and milled into dog bone shaped tension coupons using a small computer numerical control machine. A high-rate servo-hydraulic Material Testing System equipped with a custom slack adaptor, to provide constant strain rates, was used to apply tension loads to failure at an average rate of 0.5 strains/sec. The elastic modulus, yield stress, yield strain, ultimate stress, ultimate strain, and strain energy density were determined from the resulting stress versus strain curves.
Technical Paper

An Evaluation of a Fiber Optic Based Sensor for Measuring Chest and Abdominal Deflection

2005-04-11
2005-01-0745
The objective of this study was to investigate the use of a fiber optic based sensor, ShapeTape, as an instrument for measuring abdominal and chest deflection, and to compare it to the current instrument used in impact biomechanics applications, the chestband. Drift, pressure, and temperature tests were conducted for ShapeTape alone, whereas quasi-static and dynamic loading tests were conducted as comparison tests between the chestband and ShapeTape. The effects of drift and temperature on ShapeTape were very small, averaging 0.26% and 1.2% full scale changes respectively. During the pressure test at a load of 1000 N the ShapeTape sensor tested experience a 7.47% full scale voltage change. The average errors in reporting maximum deflection of the chest form during the quasi-static loading tests were 3.35% and 1.64% for ShapeTape and the chestband respectively.
Technical Paper

Lateral and Posterior Dynamic Bending of the Mid-Shaft Femur: Fracture Risk Curves for the Adult Population

2004-11-01
2004-22-0002
The purpose of this study was to develop injury risk functions for dynamic bending of the human femur in the lateral-to-medial and posterior-to-anterior loading directions. A total of 45 experiments were performed on human cadaver femurs using a dynamic three-point drop test setup. An impactor of 9.8 kg was dropped from 2.2 m for an impact velocity of 5 m/s. Five-axis load cells measured the impactor and support loads, while an in situ strain gage measured the failure strain and subsequent strain rate. All 45 tests resulted in mid-shaft femur fractures with comminuted wedge and oblique fractures as the most common fracture patterns. In the lateral-to-medial bending tests the reaction loads were 4180 ± 764 N, and the impactor loads were 4780 ± 792 N. In the posterior-to-anterior bending tests the reaction loads were 3780 ± 930 N, and the impactor loads were 4310 ± 1040 N. The difference between the sum of the reaction forces and the applied load is due to inertial effects.
Technical Paper

Upper Extremity Interaction With a Helicopter Side Airbag: Injury Criteria for Dynamic Hyperextension of the Female Elbow Joint

2004-11-01
2004-22-0007
This paper describes a three part analysis to characterize the interaction between the female upper extremity and a helicopter cockpit side airbag system and to develop dynamic hyperextension injury criteria for the female elbow joint. Part I involved a series of 10 experiments with an original Army Black Hawk helicopter side airbag. A 5th percentile female Hybrid III instrumented upper extremity was used to demonstrate side airbag upper extremity loading. Two out of the 10 tests resulted in high elbow bending moments of 128 Nm and 144 Nm. Part II included dynamic hyperextension tests on 24 female cadaver elbow joints. The energy source was a drop tower utilizing a three-point bending configuration to apply elbow bending moments matching the previously conducted side airbag tests. Post-test necropsy showed that 16 of the 24 elbow joint tests resulted in injuries.
Technical Paper

The Effect of Pregnant Occupant Position and Belt Placement on the Risk of Fetal Injury

2004-03-08
2004-01-0324
The goal of this project was to evaluate the effect of occupant seating and seatbelt placement on the risk of adverse fetal outcome from a motor vehicle crash. Unrestrained, 3-pt belt, and 3-pt belt plus airbag tests were simulated with the Virginia Tech pregnant occupant computational model in both a driver-side and passenger-side vehicle interior in frontal impacts at 35 kph. The pregnant occupant model is a small female human body model modified to include a finite element uterine model. The model was previously created and validated with abdominal force-deflection responses. Peak uterine strain was reduced by 30% to 50% in passenger-side simulations vs. driver-side simulations. However, in the unrestrained, passenger-side simulation, the pregnant occupant sustained a HIC score of 2820, suggesting immediate maternal death and a high likelihood of fetal death. Additional simulations were run in which the vertical position of the lap-belt was varied through three heights.
Technical Paper

Defining Regional Variation in the Material Properties of Human Rib Cortical Bone and Its Effect on Fracture Prediction

2003-10-27
2003-22-0012
This paper presents the results of dynamic material tests and computational modelling that elucidate the effects of regional rib mechanical properties on thoracic fracture patterns. First, a total of 80 experiments were performed using small cortical bone samples from 23 separate locations on the rib cages of four cadavers (2 male, 2 female). Each specimen was subjected to dynamic three-point bending resulting in an average strain rate of 5 ± 1.5 strain/s. Test coupon modelling was used to verify the test setup. Regional variation was defined by location as anterior, lateral, or posterior as well as by rib level 1 through 12. The specimen stiffness and ultimate stress and strain were analyzed by location and rib level. Second, these material properties were incorporated into a human body computational model. The rib cage was partitioned into anterior, lateral, and posterior segments and the material properties were varied by location using an elastic-plastic material model.
Technical Paper

A Nonlinear Finite Element Model of the Eye With Experimental Validation for the Prediction of Globe Rupture

2002-11-11
2002-22-0005
Over 2.4 million eye injuries occur each year in the US, with over 30,000 patients left blind as a result of the trauma. The majority of these injuries occur in automobile crashes, military operations and sporting activities. This paper presents a nonlinear finite element model of the eye and the results of 22 experiments using human eyes to validate for globe rupture injury prediction. The model of the human eye consists of the cornea, sclera, lens, ciliary body, zonules, aqueous humor and vitreous body. Lagrangian membrane elements are used for the cornea and sclera, Lagrangian bricks for the lens, ciliary, and zonules, and Eulerian brick elements comprise the aqueous and vitreous. Nonlinear, isotropic material properties of the sclera and cornea were gathered from uniaxial tensile strip tests performed up to rupture. Dynamic modeling was performed using LS-Dyna.
Technical Paper

Fracture Tolerance of the Small Female Elbow Joint in Compression: The Effect of Load Angle Relative to the Long Axis of the Forearm

2002-11-11
2002-22-0010
The purpose of this study was to develop a fracture tolerance for the elbow joint, or proximal ends of the ulna and radius, relative to the fracture risk under side-impact airbag loading. Forty experiments were performed on the elbow joints of small female cadavers. The energy source, a pneumatic impactor, was configured to apply compressive loads that match the onset rate, peak force, and momentum transfer of previously conducted side-impact airbag tests with small female subjects. Three initial orientations of the impact load angle relative to the longitudinal axis of the forearm were selected based on analysis of side-impact airbag tests with the instrumented dummy upper extremity. These included loading directions that are 0°, 20°, and 30° superior of the longitudinal axis of the forearm. Post-test necropsy revealed that 11 of the 40 tests resulted in chondral, osteochondral, or comminuted fractures of the proximal radial head or the distal trochlear notch.
Technical Paper

Investigation of Ocular Injuries from High Velocity Objects in an Automobile Collision

2002-03-04
2002-01-0027
The purpose of this study was to investigate ocular injuries from high velocity objects projected during an automobile collision. A computational model of the human eye was developed that included ocular structures such as the orbital fatty tissue, extraocular muscles and bony orbit. In order to validate the model, the results predicted by the model were compared to those previously found experimentally. In these experiments, porcine eyes were impacted with foam particles representative of those released during the deployment of an airbag through a seamless module cover. After simulating the identical experimental conditions, the results predicted by the model were in agreement with those found experimentally. A parametric study was conducted to determine the effect of these anatomical boundary conditions. Using MADYMO, a glass particle was projected into the eye. With the fatty tissue and muscles in place, a maximum Von Mises stress of 12.8 MPa occurred in the cornea.
Technical Paper

Analysis of upper extremity response under side air bag loading

2001-06-04
2001-06-0016
Computer simulations, dummy experiments with a new enhanced upper extremity, and small female cadaver experiments were used to analyze the small female upper extremity response under side air bag loading. After establishing the initial position, three tests were performed with the 5th percentile female hybrid III dummy, and six experiments with small female cadaver subjects. A new 5th percentile female enhanced upper extremity was developed for the dummy experiments that included a two-axis wrist load cell in addition to the existing six-axis load cells in both the forearm and humerus. Forearm pronation was also included in the new dummy upper extremity to increase the biofidelity of the interaction with the handgrip. Instrumentation for both the cadaver and dummy tests included accelerometers and magnetohydrodynamic angular rate sensors on the forearm, humerus, upper and lower spine.
Technical Paper

Interaction of the Hand and Wrist with a Door Handgrip During Static Side Air Bag Deployment: Simulation Study Using the CVS/ATB Multi-Body Program

2001-03-05
2001-01-0170
This paper presents a parametric study that utilized the CVS/ATB multi-body simulation program to investigate the interaction of the hand and wrist with a door handgrip during side air bag loading. The goal was to quantify the relative severity of various hand and handgrip positions as a guide in the selection of a test matrix for laboratory testing. The air bag was represented as a multi-body system of ellipsoidal surfaces that were created to simulate a prototype seat-mounted thorax side air bag. All simulations were set in a similar static test environment as used in corresponding dummy and cadaver side air bag testing. The occupant mass and geometric properties were based on a 5th percentile female occupant in order to represent a high-risk segment of the adult population. The upper extremity model consisted of wrist and forearm rotations that were based on human volunteer data.
Technical Paper

Small Female Upper Extremity Interaction with a Deploying Side Air Bag

1998-11-02
983148
This paper presents a study characterizing the interaction between a small female upper extremity and a deploying side air bag. The results are based on 12 tests with small female cadavers, and 15 tests with the instrumented SAE 5th percentile female upper extremity attached to the 5th percentile Hybrid III female dummy. The upper extremity was loaded by a deploying seat mounted thoracic side air bag in a static test environment. Three types of inflators were used that varied in peak pressure and pressure onset rate. Three upper extremity positions where chosen that maximized loading to the humerus and elbow joint. Upper extremity instrumentation for both the cadaver and dummy tests included accelerometers and angular rate sensors on the forearm, humerus, and upper spine. Additional instrumentation on the cadavers included strain gage rosettes on the anterior and posterior humerus.
Technical Paper

A Pneumatic Airbag Deployment System for Experimental Testing

1997-02-24
970124
This paper examines an originally designed airbag deployment system for use in static experimental testing. It consists of a pressure vessel and valve arrangement with pneumatic and electric controls. A piston functions like a valve when operated and is activated pneumatically to release the air in the tank. Once released, the air fills the attached airbag. The leading edge velocity can be controlled by the initial pressure in the tank, which can range up to 960 kPa. Three different test configurations were studied, which resulted in leading edge deployment speeds of approximately 20 m/s, 40 m/s, and 60 m/s. In experiments using this system, seven types of airbags were tested that differed in their material, coating, and presence of a tether. Data for each series of tests is provided. High speed video and film were used to record the deployments, and a pressure transducer measured the airbag's internal pressure.
X