FTIR Gas Analyzer Performance Evaluation/Qualification for Automotive Testing J2992_202007

The scope of this document focuses on the tests required by EPA to validate the performance of the FTIR system following the section in the Code of Federal Regulations Part 1065 (40 CFR 1U.1065 and hereafter referred to as “EPA Part 1065”) on the guidelines and performance criteria for various regulated gases. This document focuses on the use of continuous emissions sampling for both engine and vehicle testing. Future addenda will be needed to cover bag and other sampling techniques.
Gas components that do not currently have performance criteria but may soon be regulated are noted and EPA suggestions as to what should be required are applied. This will help ensure that the FTIR will be recognized as a valid and alternative tool for engine exhaust emissions testing. Components in engine exhaust that are specifically called out in this document include: carbon monoxide (CO), carbon dioxide (CO2), oxides of nitrogen (NO, NO2, and N2O), ammonia (NH3), methane (CH4), ethane (C2H6), and formaldehyde (H2CO). Others (for example, hydrocarbons for non-methane, non-ethane hydrocarbons (NM NE HC) or volatile organic compounds (VOC)) may be added as needed by following this standard operating procedure and determining the certification requirements from EPA or other governing bodies as required.
This SAE standard references the specific sections in the EPA Part 1065 certification test requirements (current as of April 23, 2014) for all of the steps required to provide proof of performance. The document provides the user a guideline for the FTIR gas analyzer as applied to engine or vehicle emissions testing. This document is applicable to a wide range of fuels including, but not limited to, diesel, gasoline, natural gas, liquid petroleum gas (LPG), blends, bio-fuel, and bio-fuel blends.
While this document specifically references 191 °C as the temperature used for performance validation, this may not always be the case. The temperature specification applies specifically to the raw gaseous emissions that have not been diluted. If the analysis is to be performed upon a diluted gas stream where the emission gas is at a lower temperature, then the analyzer can also be run at a lower temperature, provided that the components of interest do not condense or react prior to reaching the analyzer.
J2992_202007
2020-07-08
Latest
Revised
J2992_201504
2015-04-23
Historical
Issued

SAE MOBILUS

Subscribers can view annotate, and download all of SAE's content. Learn More »

Access SAE MOBILUS »

Members save up to 10% off list price.
Login to see discount.
Special Offer: JPaks offers a customized subscription plan that is cost-effective and allows you to choose the number of downloads and Ground Vehicle documents you need. Find more information here.
We also recommend:
TECHNICAL PAPER

Sampling System Investigation for the Determination of Semi-Volatile Organic Compounds (SVOC) Emissions From Engine Exhaust

2015-01-1062

View Details

TECHNICAL PAPER

An Alternative Technique for Low Particulate Measurement

2001-01-0218

View Details

TECHNICAL PAPER

Real Driving Emissions Procedure Development for Brazilians Conditions: FTP-75, Ethanol and Others

2021-01-0608

View Details

Get Involved

Want to participate in updating this standard?

X