Current REAFFIRMED 2020-11-10

Oil Carbon Particulate Test ARP6223

An oil sample is placed into an open top glass vial which is then inserted into a stainless steel pressure vessel. The vessel is then sealed, pressurized, and placed into a heated aluminum block bath for 18 hours. At the end of the 18 hour time period, the vessel is removed from the heat source and allowed to cool to room temperature at which time the contents of the vial are filtered and the total sediment is reported as milligrams of sediment per 20 mL of oil.
ARP6223
2020-11-10
Latest
Reaffirmed

SAE MOBILUS

Subscribers can view annotate, and download all of SAE's content. Learn More »

Access SAE MOBILUS »

Members save up to 10% off list price.
Login to see discount.