Refine Your Search

Search Results

Viewing 1 to 16 of 16
Technical Paper

Development and Testing of a Prototype Microwave Plasma Reactor for Hydrogen Recovery from Sabatier Waste Methane

2009-07-12
2009-01-2467
In the Sabatier reactor, oxygen is recovered (as water) by hydrogenation of carbon dioxide. One half of the reacted hydrogen is contained within the product water, the other half is used to form methane (CH4). Hydrogen resupply requirements for the oxygen recovery process can be minimized by reclamation of hydrogen from the methane waste. To this end, we have developed effective methods for the recovery of hydrogen from CH4 using a microwave plasma reactor. By selectively promoting the oligomerization reaction which forms hydrogen and acetylene, up to 75% of the waste hydrogen can be recovered in a manner which minimizes the carbon fouling and carbon build-up problems which drastically reduce the long-term viability of traditional methane pyrolysis methods using fixed bed and fluidized bed reactors.
Journal Article

Hydrogen Recovery by Methane Decomposition in a Microwave Plasma Reactor

2008-06-29
2008-01-2099
In the Sabatier reactor, oxygen is recovered (as water) by hydrogenation of carbon dioxide. Half of the reacted hydrogen is contained within the product water, the other half forms methane (CH4). To close the hydrogen loop, we are investigating methods for the efficient recovery of hydrogen from CH4. This paper describes microwave plasma-based methods for the thermal decomposition (cracking) of methane to produce hydrogen, elemental carbon, and related carbonaceous substances. Two primary reactor configurations have been employed in this work: 1) a quartz tube vertically oriented within a section of rectangular waveguide, and 2) waveguide transmission through a quartz window into a cylindrical vacuum chamber based multimode cavity. Hydrogen recoveries of up to 98% have been obtained. Three primary mechanisms of methane decomposition have been identified: methane pyrolysis, methane oligomerization, and methane aromatization.
Technical Paper

Microwave Enhanced Freeze Drying of Solid Waste

2007-07-09
2007-01-3266
A Microwave Enhanced Solid Waste Freeze Drying Prototype system has been developed for the treatment of solid waste materials generated during extended manned space missions. The system recovers water initially contained within wastes and stabilizes the residue with respect to microbial growth. Dry waste may then be safely stored or passed on to the next waste treatment process. Operating under vacuum, microwave power provides the energy necessary for sublimation of ice contained within the waste. This water vapor is subsequently collected as relatively pure ice on a Peltier thermoelectric condenser as it travels en route to the vacuum pump. In addition to stabilization via dehydration, microwave enhanced Freeze Drying reduces the microbial population (∼90%) in the waste.
Technical Paper

Microwave Powered Gravitationally Independent Medical Grade Water Generation

2007-07-09
2007-01-3176
The on-demand production of Medical Grade Water (MGW) is a critical biomedical requirement for future long-duration exploration missions. Potentially, large volumes of MGW may be needed to treat burn victims, with lesser amounts required to reconstitute pharmacological agents for medical preparations and biological experiments, and to formulate parenteral fluids during medical treatment. Storage of MGW is an untenable means to meet this requirement, as are nominal MGW production methods, which use a complex set of processes to remove chemical contaminants, inactivate all microorganisms, and eliminate endotoxins, a toxin originating from gram-negative bacteria cell walls. An innovative microgravity compatible alternative, using a microwave-based MGW generator, is described in this paper. The MGW generator efficiently couples microwaves to a single-phase flowing stream, resulting in super-autoclave temperatures.
Technical Paper

Development and Testing of a Microwave Powered Solid Waste Stabilization and Water Recovery System

2006-07-17
2006-01-2182
A Microwave Powered Solid Waste Stabilization and Water Recovery Prototype system has been developed for the treatment of solid waste materials generated during extended manned space missions. The system recovers water initially contained within wastes and stabilizes the residue with respect to microbial growth. Dry waste may then be safely stored or passed on to the next waste treatment process. Using microwave power, water present in the solid waste is selectively and rapidly heated. Liquid phase water flashes to steam and superheats. Hot water and steam formed in the interior of waste particles create an environment that is lethal to bacteria, yeasts, molds, and viruses. Steam contacts exposed surfaces and provides an effective thermal kill of microbes, in a manner similar to that of an autoclave. Volatilized water vapor is recovered by condensation.
Technical Paper

Magnetically Assisted Gasification of Solid Wastes: Comparison of Reaction Strategies

2005-07-11
2005-01-3081
Gradient magnetically assisted fluidized bed (G-MAFB) methods are under development for the decomposition of solid waste materials in microgravity and hypogravity environments. The G-MAFB has been demonstrated in both laboratory and microgravity flight experiments. In this paper we summarize the results of gasification reactions conducted under a variety of conditions, including: combustion, pyrolysis (thermal decomposition), and steam reforming with and without oxygen addition. Wheat straw, representing a typical inedible plant biomass fraction, was chosen for this study because it is significantly more difficult to gasify than many other typical forms of solid waste such as food scraps, feces, and paper. In these experiments, major gasification products were quantified, including: ash, char, tar, carbon monoxide, carbon dioxide, methane, oxygen, and hydrogen.
Technical Paper

Magnetically Assisted Filtration of Solid Wastes: Laboratory and Flight Experiments

2005-07-11
2005-01-3082
Solid wastes can be separated from aqueous streams and concentrated by filtration in a magnetically assisted fluidized bed. In this work the filtration of solid waste materials using filter beds consisting of granular ferromagnetic media is demonstrated. The degree of bed consolidation (or conversely fluidization) is controlled by the application of magnetic forces. In the Magnetically Assisted Gasification (MAG) process, solids are first entrapped by filtration, and then fluidized and transferred to a high temperature reactor where they are thermally decomposed. The maximum particle loading for the filter bed is determined by the intergranular void space. Using magnetic methods, it is possible to manipulate the degree of compaction as the filtration progresses to increase the void space and thereby maximize the loading capacity and efficiency of the filter. This process is completely compatible with operation in microgravity and hypogravity.
Technical Paper

Development of Enabling Technologies for Magnetically Assisted Gasification of Solid Wastes

2003-07-07
2003-01-2374
Magnetically Assisted Gasification (MAG) is a relatively new concept for the destruction of solid wastes aboard spacecraft, lunar and planetary habitations. Three sequential steps are used to convert the organic constituents of waste materials into useful gases: filtration, gasification, and ash removal. In the filtration step, an aqueous suspension of comminuted waste is separated and concentrated using a magnetically consolidated depth filter composed of granular ferromagnetic media. Once the filter is fully loaded, the entrapped solids are thermochemically gasified via a variety of mechanisms including pyrolysis, isomerization, and oxidation reactions. Finally, the inorganic ash residue is removed from the magnetic media by fluidization and trapped downstream by filtration. Importantly, for each of these steps, the degree of consolidation or fluidization of the granular ferromagnetic media is controlled using magnetic forces.
Technical Paper

Development and Testing of a Microwave Powered Regenerable Air Purification Technology Demonstrator

2002-07-15
2002-01-2403
Dielectric heating via microwave irradiation of contaminant laden sorbents offers distinct advantages in comparison to conventional thermal regeneration techniques. High temperatures may be achieved very rapidly because electromagnetic energy is absorbed directly by the sorbent material. A Technology Demonstrator, incorporating efficient rectangular waveguide based sorbent cartridge designs and effective microwave transmission systems was designed, fabricated and tested. Importantly, the performance of the Molecular Sieve 13X Waveguide Cartridge for the removal of water vapor, the Molecular Sieve 5A Waveguide Cartridge for the removal of CO2, and the Activated Carbon Waveguide Cartridge for removal of volatile organics from air, were each validated by successive sorption/ microwave desorption cycles.
Technical Paper

Microwave-Powered Thermal Regeneration of Sorbents for CO2, Water Vapor and Trace Organic Contaminants

1997-07-01
972430
Feasibility of the use of microwave heating to achieve fast and efficient thermal regeneration of sorbents for the removal of carbon dioxide, water vapor, and trace organics from contaminated air streams has been conclusively demonstrated. The use of microwave power offers several advantages, including: improved heat transfer, lower thermal losses, improved power utilization, and enhanced operational capabilities. During the initial research, the sorption and microwave-powered thermal desorption of acetone, trichloroethylene (TCE), carbon dioxide, and water vapor was studied at 2.45 GHz using a rectangular waveguide based test apparatus. Both activated carbon and Carbosieve S-III were identified as excellent microwave regenerable sorbents for use in the removal of airborne organics. Water loaded silica gel, Molecular Sieve 13X, and Molecular Sieve 5A were also effectively regenerated under microwave irradiation at this frequency.
Technical Paper

Development and Testing of the Microwave Sterilizable Access Port Prototype

1996-07-01
961567
The ability to aseptically remove samples and products, and the capability for addition of materials to sterile or otherwise microbially susceptible systems have always been compromised by the lack of a reliable means of sterilizing the mating fixtures. Cultures of mammalian cells are particularly vulnerable to microbial contamination due to the complexity of nutrient media and the lengthy periods required for cell growth. The Microwave Sterilizable Access Port has been developed to overcome this limitation. The system consists of three primary components: a microwave power source, a combined sterilization chamber/in-line valve port assembly, and a specimen transfer interface. Microwave energy is transmitted via coaxial cable to a small pressurized chamber that serves as a sterile transition between the surrounding environment and the system during transfer of materials.
Technical Paper

Chemiluminescent Ethanol Biosensor Development

1995-07-01
951686
The investigation and development of a chemiluminescence based ethanol detection concept into a biosensor system is described. The biosensor uses alcohol oxidase to catalyze the reaction of short chain primary alcohols with elemental oxygen to produce hydrogen peroxide and the corresponding aldehyde. The reaction of hydrogen peroxide with an organic luminophore in the presence of a sufficient electric field results in emission of blue light with peak intensity at 425nm. The chemiluminescent light intensity is directly proportional to the alcohol concentration of the sample. The aqueous phase chemistry required for sensor operation is implemented using solid phase modules which adjust the pH of the influent stream, catalyze the oxidation of alcohol, provide the controlled addition of the luminophore to the flowing aqueous stream, and minimize the requirement for expendables. Precise control of the pH has proven essential for the long-term sustained release of the luminophore.
Technical Paper

Advanced Development of the Regenerative Microbial Check Valve

1993-07-01
932175
The Microbial Check Valve (MCV) is a reloadable flow-through canister containing iodinated ion exchange resin, which is used aboard the Shuttle Orbiter as a disinfectant to maintain water potability. The MCV exhibits a significant contact kill and imparts a biocidal residual I2 concentration to the effluent. MCVs in current use have nominal 30 day lives. MCVs baselined for Space Station Freedom will have 90 day lives, and will require replacement 120 times over 30 years. Means to extend MCV life are desirable to minimize resupply penalties. New technology has been developed for fully autonomous in situ regeneration of an expended MCV canister. The Regenerative Microbial Check Valve (RMCV) consists of an MCV, a packed bed of crystalline I2, a flow diverter valve, an in-line iodine monitor and a microcontroller. During regeneration, flow is directed first through the packed I2 bed and then into the MCV where the resin is replenished.
Technical Paper

Single Phase Space Laundry Development

1993-07-01
932092
This paper describes a newly designed, 2.7 Kg (6 pound) capacity, laundry machine called the Single Phase Space Laundry (SPSL). The machine was designed to wash and dry crew clothing in a micro-gravity environment. A prototype unit was fabricated for NASA-JSC under a Small Business Innovative Research (SBIR) contract extending from September 1990 to January 1993. The unit employs liquid jet agitation, microwave vacuum drying, and air jet tumbling, which was perfected by KC-135 zero-g flight testing. Operation is completely automated except for loading and unloading clothes. The unit uses about 20 percent less power than a conventional household appliance.
Technical Paper

Regenerable Microbial Check Valve: Life Cycle Tests Results

1992-07-01
921316
The Microbial Check Valve (MCV) is a canister containing an iodinated ion exchange resin and is used on the Shuttle Orbiter to provide microbial control of potable water. The MCV provides a significant contact kill, and imparts a biocidal iodine residual to the water. The Orbiter MCV has a design life of 30 days. For longer duration applications, such as Space Station Freedom, an extended life is desirable to avoid resupply penalties. A method of in situ MCV regeneration with elemental iodine is being developed. During regeneration water en route to the MCV first passes through a crystalline iodine bed where a concentration between 200 - 300 mg/L I2 is attained. When introduced into the MCV, this high concentration causes an equilibrium shift towards iodine loading, effecting regeneration of the resin. After regeneration normal flow is re-established. Life cycle regeneration testing is currently in progress.
Technical Paper

Chemistry and Kinetics of I2 Loss in Urine Distillate and Humidity Condensate

1992-07-01
921314
A significant decline in molecular iodine concentration is associated with the iodination of heavily contaminant-laden process water streams such as humidity condensate and urine distillate. Iodine loss is attributable to the reaction of this biocide with organic constituents. This phenomenon has been investigated using time resolved molecular absorption spectrophotometry of iodinated ersatz humidity condensates and iodinated ersatz urine distillates across the ultraviolet and visible spectral regions. Rates of iodine loss have also been studied using single contaminant systems at equivalent concentrations. The predominant reactive species have been identified as thiourea and formic acid. Pseudo-first order rate constants have been determined for ersatz contaminant model mixtures and for individual reactive constituents. Second order rate constants have been determined for the bimolecular reaction of iodine and formic acid.
X