Technical Paper

Mechanisms of Traumatic Rupture of the Aorta and Associated Peri-isthmic Motion and Deformation

2008-11-03
2008-22-0010
This study investigated the mechanisms of traumatic rupture of the aorta (TRA). Eight unembalmed human cadavers were tested using various dynamic blunt loading modes. Impacts were conducted using a 32-kg impactor with a 152-mm face, and high-speed seatbelt pretensioners. High-speed biplane x-ray was used to visualize aortic motion within the mediastinum, and to measure deformation of the aorta. An axillary thoracotomy approach was used to access the peri-isthmic region to place radiopaque markers on the aorta. The cadavers were inverted for testing. Clinically relevant TRA was observed in seven of the tests. Peak average longitudinal Lagrange strain was 0.644, with the average peak for all tests being 0.208 ± 0.216. Peak intraluminal pressure of 165 kPa was recorded. Longitudinal stretch of the aorta was found to be a principal component of injury causation. Stretch of the aorta was generated by thoracic deformation, which is required for injury to occur.
Technical Paper

Development and Evaluation of a Proposed Neck Shield for the 5th Percentile Hybrid III Female Dummy

2005-11-09
2005-22-0022
Frontal airbag interaction with the head and neck of the Hybrid III family of dummies may involve a nonbiofidelic interaction. Researchers have found that the deploying airbag may become entrapped in the hollow cavity behind the dummy chin. This study evaluated a prototype neck shield design, the Flap Neck Shield, for biofidelic response and the ability to prevent airbag entrapment in the chin/jaw cavity. Neck pendulum calibration tests were conducted for biofidelity evaluation. Static and dynamic airbag deployments were conducted to evaluate neck shield performance. Tests showed that the Flap Neck Shield behaved in a biofidelic manner with neck loads and head motion within established biofidelic limits. The Flap Neck Shield did not alter the neck loads during static or dynamic airbag interactions, but it did consistently prevent the airbag from penetrating the chin/jaw cavity.
Technical Paper

Development of a New Standard for Measurement of Impulse Noise Associated With Automotive Inflatable Devices

2005-05-16
2005-01-2398
The SAE Recommended Practice for measuring impulse noise from airbags, SAE J247, “Instrumentation for Measuring Acoustic Impulses within Vehicles”, was first published in 1971 and last affirmed in 1987. Many advances have occurred in understanding and technology since that time. Work in the automotive industry to investigate the characteristics of noise from airbag deployments has shown that large components of low frequency noise can be present when an airbag deploys in a closed vehicle. Others have shown that this low frequency noise can have a protective effect on the ear. Likewise, work for many years at the US Army Research Lab has investigated the risk of hearing loss for a human subjected to an acoustic impulse. That research led to the creation and validation of a mathematical model of the human ear, called Auditory Hazard Assessment Algorithm - Human (AHAAH).
Technical Paper

The Effect of Loading Rate on the Degree of Acute Injury and Chronic Conditions in the Knee After Blunt Impact

2000-11-01
2000-01-SC20
Lower extremity injuries due to automobile accidents are often overlooked, but can have a profound societal cost. Knee injuries, for example, account for approximately 10% of the total injuries. Fracture of the knee is not only an acute issue but may also have chronic, or long term, consequences. The criterion currently used for evaluation of knee injuries in new automobiles, however, is based on experimental impact data from the 70''s using seated human cadavers. These studies involved various padded and rigid impact interfaces that slightly alter the duration of contact. Based on these data and a simple mathematical model of the femur, it appears fracture tolerance increases as contact duration shortens. In contrast, more recent studies have shown mitigation of gross fractures of the knee itself using padded interfaces. The use of padded interfaces, however, result in coincidental changes in contact duration and knee contact area.
Technical Paper

Axial Compressive Load Response of the 90Md Flexed Human Tibiofemoral Joint

1999-10-10
99SC08
National Accident Sampling System (NASS) data, for the years 1993-1995, suggests a high frequency of tibiofemoral joint fractures among automotive accident victims. In addition, the NASS data also suggests that these injuries may be attributable to direct axial loading via the floor pan and/or the foot controls. Hirsch and Sullivan (1965), and Kennedy and Bailey (1968) conducted quasi-static fracture experiments axially compressing human tibiofemoral joints at low rates of loading and low angles of flexion. Hirsch and Sullivan observed a mean fracture load of approximately 8 kN compared to approximately 16 kN in the Kennedy and Bailey study. The current tibiofemoral joint injury criterion used in anthropomorphic dummies is based on Hrisch and Sullivan''s data. The current study involved impact experiments on human tibiofemoral joints (aged 71.4±11.2) directed in a superior direction along the axis of the tibia with the joint flexed 90°.