Testing Method to Determine the Thermal Parasitics of the NICMOS Cryogenic Cooler 2001-01-2257

The NICMOS Cryogenic Cooler (NCC) is a turbomachine-based reverse-Brayton cycle cryocooler combined with a single-phase cryogenic heat transport loop. The NCC will be installed on the Hubble Space Telescope (HST) on a future servicing mission, and will provide refrigeration to the Near Infrared Camera and Multi-Object Spectrometer (NICMOS) detectors that were previously cooled by a dewar of sublimating solid nitrogen. The NCC is designed to remove a total of 7 W of heat and maintain the NICMOS detectors at 77 K. The 7 W heat load is comprised of the dissipation from the NICMOS detectors and the parasitics into the heat transport loop.
During testing of the NCC it was crucial to quantify parasitic heat loads in the heat transport loop since this governs the minimum temperature that can be achieved at the NICMOS detectors. The determination of parasitics was aided by the installation of a well-instrumented section of tubing, referred to as a shunt, that connected the inlet and outlet heat transport lines of the NCC. This shunt and its instrumentation were thermally isolated from the NCC environment so as not to introduce any additional parasitics. Using this shunt, we were able to determine the mass flow rate of the neon cooling gas and the distribution of parasitics throughout the heat transport loop of the NCC.
The value of the method developed herein is twofold: (1) it provided a means to reliably quantify the cooling capability of the two-loop NCC; and (2) it provided a means to quantitatively evaluate modifications to the NCC to lower NICMOS detector temperature for better detector performance.

SAE MOBILUS

Subscribers can view annotate, and download all of SAE's content. Learn More »

Access SAE MOBILUS »

Members save up to 16% off list price.
Login to see discount.
Special Offer: Download multiple Technical Papers each year? TechSelect is a cost-effective subscription option to select and download 12-100 full-text Technical Papers per year. Find more information here.
We also recommend:
TECHNICAL PAPER

Strategy For Modeling of Large A/C Fluid Systems

2004-01-3093

View Details

TECHNICAL PAPER

Shaping Tomorrow's Vehicles: SMC Automotive Alliance Steps Up to Recycling Challenge

950834

View Details

STANDARD

Surface Texture, Roughness (Ra), Peak Count(Pc), and Mean Profile Spacing, (Rsm) Measurement of Metallic Coated and Uncoated Steel Sheet/Strip to be Formed and/or to be Painted

J911_201704

View Details

X