Predictive Testing for GEO and LEO Lithium Ion Space Cells 1999-01-1386
Very little published data exist for the lithium ion chemistry showing that it will meet the rigors of GEO or LEO satellites. This paper reveals that the graphite/LiNiO2 chemistry has achieved 133,000 discharges at 30% DOD in 18650 cells. Full scale 40 Ah cell data predicts ∼ 4000 cycles for 60% DOD and above 100,000 cycles for 20 and 30% DOD.
Citation: Staniewicz, R., d'Ussel, L., Kasztejna, P., and Gollatz, W., "Predictive Testing for GEO and LEO Lithium Ion Space Cells," SAE Technical Paper 1999-01-1386, 1999, https://doi.org/10.4271/1999-01-1386. Download Citation
Author(s):
Robert J. Staniewicz, Louis d'Ussel, Paul Kasztejna, William Gollatz
Affiliated:
SAFT ATD, R&D Center
Pages: 5
Event:
Aerospace Power Systems Conference
ISSN:
0148-7191
e-ISSN:
2688-3627
Also in:
Aerospace Power Systems Conference Proceedings-P-341, SAE 1999 Transactions - Journal of Aerospace-V108-1
Related Topics:
Lithium
Graphite
Satellites
SAE MOBILUS
Subscribers can view annotate, and download all of SAE's content.
Learn More »