The Role of Suction Line Heat Exchanger in Transcritical R744 Mobile A/C Systems 1999-01-0583
Transcritical R744 systems are under consideration for use in mobile air conditioning. Experimental results indicate that the inherent thermodynamic shortcomings of R744 could be overcome by exploiting inherent advantages in transport properties, pressure drop, and other characteristics. This paper describes one possible way to improve both capacity and energy efficiency of the R744 system for the car air conditioning. It considers the use of a suction line heat exchanger. Four different configurations of the prototype system were tested: without heat exchanger, and with three coaxial heat exchangers having lengths 1.0, 1.5 and 2.0m. All heat exchangers were made from identical pipes.
Results show that both the capacity and the coefficient of performance could be increased by up to 25%. Greater influence is registered at the higher temperatures of the air to the gas cooler.
The results also demonstrate the extent to which suction line heat exchangers can increase compressor discharge temperatures, thereby complicating the task of compressor design and introducing reliability risks.
Citation: Boewe, D., Yin, J., Park, Y., Bullard, C. et al., "The Role of Suction Line Heat Exchanger in Transcritical R744 Mobile A/C Systems," SAE Technical Paper 1999-01-0583, 1999, https://doi.org/10.4271/1999-01-0583. Download Citation
Author(s):
D. Boewe, J. Yin, Y. C. Park, C. W. Bullard, P. S. Hrnjak
Affiliated:
Air Conditioning and Refrigeration Center (ACRC), University of Illinois
Pages: 10
Event:
International Congress & Exposition
ISSN:
0148-7191
e-ISSN:
2688-3627
Related Topics:
Heat exchangers
Air conditioning
Energy conservation
Thermodynamics
Compressors
SAE MOBILUS
Subscribers can view annotate, and download all of SAE's content.