Refine Your Search

Search Results

Viewing 1 to 3 of 3
Technical Paper

Performance Validation and Optimization of the Columbus Orbital Facility Condensing Heat Exchanger and Filter Assembly

1998-07-13
981776
A condensing heat exchanger and filter assembly (CHXFA) has been developed by SECAN/AlliedSignal under a contract from Daimler-Benz Aerospace, Dornier, as part of a European Space Agency program. The CHXFA is part of the Environmental Control and Life Support System (ECLSS) of the Columbus Orbital Facility (COF), the European Laboratory Module of the International Space Station (ISS). This paper gives an overview of the component and assembly level testing performed to validate the CHXFA, and describes some of the design features incorporated to meet the challenging requirements of the Columbus Orbital Facility.
Technical Paper

Design of Orbital Replacement Units for the Columbus Orbital Facility Condensing Heat Exchanger and Filter Assembly

1998-07-13
981775
A condensing heat exchanger and filter assembly (CHXFA) has been developed by SECAN/AlliedSignal under a contract from Dornier Daimler-Benz as part of a European Space Agency program. The CHXFA is part of the Environmental Control and Life Support System (ECLSS) of the Columbus Orbital Facility (COF), the European Laboratory Module of the International Space Station (ISS). Although the COF CHXFA has a lifetime requirement of 10 years, some of the assembly components have been designated orbital replacement units (ORU's), which means that they must be designed to be replaceable “on-orbit”, in micro-gravity conditions. The CHXFA contains a filter to remove particulates from the air stream, and a differential pressure sensor to monitor pressure drop across the filter. The filter is a limited lifetime ORU, which will be periodically replaced as part of routine maintenance. The differential pressure sensor is also designated as an ORU.
Technical Paper

Columbus Orbital Facility Condensing Heat Exchanger and Filter Assembly

1997-07-01
972409
Space environmental control systems must control cabin temperature and humidity. This can be achieved by transferring the heat load to a circulating coolant, condensing the humidity, and separating the condensate from the air stream. In addition, environmental control systems may be required to remove particulate matter from the air stream. An assembly comprised of a filter, a condensing heat exchanger, a thermal control valve, and a liquid carryover sensor, is used to achieve all these requirements. A condensing heat exchanger and filter assembly (CHXFA) is being developed and manufactured by SECAN/AlliedSignal under a contract from Dornier Daimler-Benz as part of a European Space Agency program. The CHXFA is part of the environmental control system of the Columbus Orbital Facility (COF), the European laboratory module of the International Space Station (ISS).
X