Technical Paper

Reference PMHS Sled Tests to Assess Submarining of the Small Female

2018-11-12
2018-22-0003
In the last decade, extensive efforts have been made to understand the physics of submarining and its consequences in terms of abdominal injuries. For that purpose, 27 Post Mortem Human Subject (PMHS) tests were performed in well controlled conditions on a sled and response corridors were provided to assess the biofidelity of dummies or human body models. All these efforts were based on the 50th percentile male. In parallel, efforts were initiated to transfer the understanding of submarining and the prediction criteria to the THOR dummies. Both the biofidelity targets and the criteria were scaled down from the 50th percentile male to the 5th percentile THOR female. The objective of this project was to run a set of reference PMHS tests in order to check the biofidelity of the THOR F05 in terms of submarining. Three series of tests were performed on nine PMHS, the first one was designed to avoid submarining, the second and third ones were designed to result in submarining.
Technical Paper

Relation Between Sacroilium and Other Pelvic Fractures Based on Real-World Automotive Accidents

2018-11-12
2018-22-0010
The study firstly aimed at looking whether sacroilium (SI) fractures could be sustained as unique pelvic injuries in side impact real world automotive accidents. Secondarily, the sacroilium fractures observed in conjunction with other pelvic fractures were analyzed to investigate the existence of injury association patterns. Two real world accident databases were searched for SI fractures. The occupants selected were front car passengers older than 16, involved in side, oblique or frontal impact, with AIS2+ pelvic injuries. In frontal impact, only the belted occupants were selected. The cases were sorted by the principal direction of force (dof) and the type of pelvic injury, namely SI, pubic rami, iliac wing, acetabulum, pubic symphysis, and sacrum injuries. The relation between SI and pubic rami injuries were investigated first. The first database is an accident database composed of cases collected in France by car manufacturers over a period of approximately 40 years.
Technical Paper

Update of the WorldSID 50th Male Pelvic Injury Criterion and Risk Curve

2018-04-03
2018-01-0539
Petit et al. 2015 and Lebarbé et al. 2016 reported on two studies where the injury mechanism and threshold of the sacroiliac joint were investigated in two slightly oblique crash test conditions from 18 Post Mortem Human Subjects (PMHS) tests. They concluded that the sacroiliac joint fractures were associated with pubic rami fractures. These latter being reported to occur first in the time history. Therefore it was recommended not to define a criterion specific for the sacroiliac joint. In 2012, injury risk curves were published for the WorldSID dummy by Petitjean et al. For the pelvis, dummy and PMHS paired tests from six configurations were used (n = 55). All of these configurations were pure lateral impacts. In addition, the sacroiliac joint and femur neck loads were not recorded, and the dummy used was the first production version (WorldSID revision 1). Since that time, the WorldSID was updated several times, including changes in the pelvis area.
Technical Paper

Investigation of Pelvic Injuries on Eighteen Post Mortem Human Subjects Submitted to Oblique Lateral Impacts

2016-11-07
2016-22-0005
The aim of this study was to investigate the sacroiliac joint injury mechanism. Two test configurations were selected from full scale car crashes conducted with the WorldSID 50th dummy resulting in high sacroiliac joint loads and low pubic symphysis force, i.e. severe conditions for the sacroiliac joint. The two test conditions were reproduced in laboratory using a 150-155 kg guided probe propelled respectively at 8 m/s and 7.5 m/s and with different shapes and orientations for the plate impacting the pelvis. Nine Post Mortem Human Subject (PMHS) were tested in each of the two configurations (eighteen PMHS in total). In order to get information on the time of fracture, eleven strain gauges were glued on the pelvic bone of each PMHS. Results - In the first configuration, five PMHS out of nine sustained AIS2+ pelvic injuries. All five presented sacroiliac joint injuries associated with pubic area injuries.
Technical Paper

Reference PMHS Sled Tests to Assess Submarining

2015-11-09
2015-22-0008
Sled tests focused on pelvis behavior and submarining can be found in the literature. However, they were performed either with rigid seats or with commercial seats. The objective of this study was to get reference tests to assess the submarining ability of dummies in more realistic conditions than on rigid seat, but still in a repeatable and reproducible setup. For this purpose, a semi-rigid seat was developed, which mimics the behavior of real seats, although it is made of rigid plates and springs that are easy to reproduce and simulate with an FE model. In total, eight PMHS sled tests were performed on this semi-rigid seat to get data in two different configurations: first in a front seat configuration that was designed to prevent submarining, then in a rear seat configuration with adjusted spring stiffness to generate submarining. All subjects sustained extensive rib fractures from the shoulder belt loading.
Technical Paper

A Comparison of Sacroiliac and Pubic Rami Fracture Occurrences in Oblique Side Impact Tests on Nine Post Mortem Human Subjects

2015-11-09
2015-22-0002
The WorldSID dummy can be equipped with both a pubic and a sacroiliac joint (S-I joint) loadcell. Although a pubic force criterion and the associated injury risk curve are currently available and used in regulation (ECE95, FMVSS214), as of today injury mechanisms, injury criteria, and injury assessment reference values are not available for the sacroiliac joint itself. The aim of this study was to investigate the sacroiliac joint injury mechanism. Three configurations were identified from full-scale car crashes conducted with the WorldSID 50th percentile male where the force passing through the pubis in all three tests was approximately 1500 N while the sacroiliac Fy / Mx peak values were 4500 N / 50 Nm, 2400 N / 130 Nm, and 5300 N / 150 Nm, respectively. These tests were reproduced using a 150 kg guided probe impacting Post Mortem Human Subjects (PMHS) at 8 m/s, 5.4 m/s and 7.5 m/s.
Technical Paper

Biofidelic Responses of the THOR-NT and Hybrid III Based on Component Tests

2008-04-14
2008-01-0520
Component tests were conducted in order to evaluate the biofidelity of the THOR-NT on the head, neck, thorax, abdomen, face, femur, and lower extremity (THOR-Lx). The biofidelity of the dummy was evaluated by comparing its biofidelic responses with the PMHS response corridors. Likewise, component tests on each body part of the Hybrid III were conducted, and the biofidelity between THOR-NT (THOR-Lx) and Hybrid III were compared. The THOR tests were subject to test procedures established by GESAC, Inc./NHTSA; the THOR-Lx tests were subject to NHTSA/VRTC procedures. Responses on the head and femur of both the THOR-NT and Hybrid III were within the PMHS response corridors. However, for other body parts - although each component of THOR-NT did not yield results that satisfied all the PMHS response corridors - the responses of THOR-NT were closer to the corridors than those of the Hybrid III.
Technical Paper

Below Knee Impact Responses using Cadaveric Specimens

2004-11-01
2004-22-0004
Knee injuries represent about 10% of all injuries suffered during car crashes. Efforts to assess the injury risk to the posterior cruciate ligament (PCL) have been based on a study available in the literature (Viano et al., 1978), in which only two of the five knees tested had PCL ruptures. The aims of the current study were to repeat the study with a higher number of samples, study the effects of other soft tissues on knee response, and assess the adequacy of the experimental setup for the identification of a PCL tolerance. A total of 14 knees were tested using a high-speed materials testing machine. Eight were intact knees (with the patella and all the muscular and ligamentous structures), three were PCL-only knees (patella and all the muscular and ligamentous structures other than the PCL removed), and the last three were PCL-only knees with the tibia protected from bending fracture.
Technical Paper

Evaluations of the Recommended New Parts for the Hybrid III Dummy - Neck Shield and Hip Joint

1996-02-01
960450
Three improvements for the Hybrid III dummy parts are proposed by NHTSA, they are the neck shield, hip joint, and ankle joint In this paper, two modifications of the three, the neck shield and hip joint, are evaluated The recommended neck shield was tested and compared to the previous type to investigate the following, 1 The effect of the neck moment on both the recommended and previous type, and 2 The comparison between the stiffness of the neck shield and human soft tissue under the chin, using a volunteer static test From these tests, the new recommended neck shield performed better than the previous type with respect to both biofidelity and the effect on the neck moment test The neck shield for 5th-percentile female was also considered The hip joint recommended by NHTSA was compared with the modified joint and pelvis proposed by Toyota It was found that the NHTSA's recommended hip joint eliminated the hip lock due to metal-to-metal contact It was also found that the maximum rotation angle of the NHTSA's recommended hip joint was less than that of the hip joint and pelvis proposed by Toyota