A Trade Study Method for Determining the Design Parameter of CELSS Subsystems

1992-07-01
921198
Developments of many subsystems, such as gas separater, water purifier, decomposition unit of waste materials and others, are necessary to construct the closed loop life support test facility for studying the material circulationin earth environment and for human habitation in space. On the other hand, in order to develop and integrate these subsystems infacility, the designing paramaters of each subsystem are to be determined based on the required material flows estimation. The required material flows are very complicated and difficult to be analyzed. Therefore the trade study method for determining the design paramaters of each subsystem is to be integrated based on the break down of system configulation Level as below. Level-0 is the material flow level between the total closed loop life support facility and outside. Level-1 is the material flow level between the plantation, habitat and animal breeding modules and their supporting systems.