Refine Your Search

Search Results

Viewing 1 to 5 of 5
Technical Paper

Appliance of High EGR Rates With a Short and Long Route EGR System on a Heavy Duty Diesel Engine

2007-04-16
2007-01-0906
The goal of this work was to investigate the possibilities of applying high EGR rates with low NOx and PM emission levels on a two-stage turbocharged 12 liter heavy duty diesel engine. The EGR is applied by using a long and short route EGR system. For the ESC operating points A25 and C100 EGR is applied, such that the NOx emission is 0.5 g/kWh. Lowest PM level and BSFC are achieved when long route EGR is applied in A25 and short route is applied in C100. Increasing the fuel line pressure is an effective way to reduce PM at high EGR rate engine running conditions. At a fuel line pressure of 2400 bar PM emission are 0.06 g/kWh for A25 and 0.54 g/kWh for C100. At C100 the PM reduction coincides with also a significant fuel consumption improvement. Retarding the injection timing at C100 can improve the PM emission further to a level of 0.13 g/kWh at the expense of an increase in BSFC.
Technical Paper

Engine Demonstration of Microwave Assisted Particulate Trap Regeneration

2005-05-11
2005-01-2141
In this study a microwave assisted particulate trap regeneration system has been developed. Microwave technology typically shows uneven temperature distribution in a trap. In this research an innovative technique is introduced: a so-called circular polarizer for generating a more even energy distribution in the trap. Experimental work has been performed on a 1.2 l TDI engine on an engine dynamometer. A cordierite wall-flow trap was located in the exhaust pipe. Experiments have been performed with variation of temperature at the start of regeneration, energy input duration and external combustion air flow. It has been observed that the exhaust gas flow of the engine, even at idle, is too high for maintaining propagating flame fronts. It can be concluded that microwave regeneration with a low-power microwave generator of about 1 kW must be applied in a multiple branch trap system or regeneration events must be applied in periods when the engine is not running.
Technical Paper

Single Bank NOx Adsorber for Heavy Duty Diesel Engines

2003-05-19
2003-01-1885
In a NOx adsorber programme the feasibility for applying this technology to heavy duty diesel engines was investigated. After modelling and simulations for realising best λ < 1 engine conditions a platform was build which was used to obtain good NOx adsorber regeneration settings in a number of steady state key points without violating pre-defined limits. With these results the NOx adsorber was evaluated and tested. Besides establishing NOx conversions and BSFC penalties the programme also looked at the adsorber capabilities of dealing with sulphur poisoning and how well the adsorber could be de-sulphurised. This programme showed clearly the stronger and weaker points in the NOx adsorber technology for heavy duty application. From NOx conversion - BSFC penalty trade off curves it became clear that at lower loads high conversions (> 90%) with small fuel penalties (< 2.5%) were possible. However at high load the conversions were reduced (< 70%) and the fuel penalties increased (> 6%).
Technical Paper

Engine Dynamometer and Vehicle Performance of a Urea SCR-System for Heavy-Duty Truck Engines

2002-03-04
2002-01-0286
The application of SCR deNOx aftertreatment was studied on two about 12 liter class heavy-duty diesel engines within a consortium project. Basically, the system consists of a dosage system for aqueous urea injection and a vanadia based SCR catalyst, without an upstream or downstream oxidation catalyst. The urea injection system for a DAF and a Renault V.I. (Véhicules Industriels) diesel engine was calibrated on the engine test bench taking into account dynamic effects of the catalyst. For both engine applications NOx reduction was 81% to 84% over the ESC and 72% over the ETC. CO emission increased up to 27%. PM emission is reduced by 4 to 23% and HC emission is reduced by more than 80%. These results are achieved with standard diesel fuel with about 350 ppm sulfur. The test engines and SCR deNOx systems were built into a DAF FT95 truck and a Renault V.I. Magnum truck.
Technical Paper

DAF Euro-4 Heavy Duty Diesel Engine with TNO EGR system and CRT Particulates Filter

2001-05-07
2001-01-1947
This paper reports on a study of the TNO venturi EGR system and the Johnson Matthey CRT particulates trap on a DAF 355 kW engine. The results obtained indicate that this EGR-CRT combination is an effective means to achieve EURO-4 emission level, while maintaining good fuel economy. EGR strategy, injection timing and air-fuel ratio were optimised in such a way that good regeneration conditions were obtained across most of the engine operating map. Also transient EGR control is optimised to combine low NOx emission during the ETC with good driveability and good engine out particulates emission. The size of the oxidation catalyst in the CRT was investigated. It appeared that the larger oxidation catalyst showed a better regeneration performance during a low temperature duty-cycle. Negative aspects of a larger oxidation catalyst are increased costs and increased NO2 emission (because of the catalyst ability to oxidise more NO into NO2).
X