Refine Your Search

Search Results

Author:
Viewing 1 to 7 of 7
Technical Paper

ISS IATCS Coolant Loop Biocide Implementation

2008-06-29
2008-01-2159
The proliferation and growth of microorganisms in the Internal Active Thermal Control System (IATCS) aboard the International Space Station (ISS) has been of significant concern since 2001. Initial testing and assessments of biocides to determine bacterial disinfection capability, material compatibility, stability (rate of oxidative degradation and identification of degradation products), solubility, application methodology, impact on coolant toxicity hazard level, and impact on environmental control and life support systems identified a prioritized list of acceptable biocidal agents including glutaraldehyde, ortho-phthalaldehyde (OPA), and methyl isothiazolone. Glutaraldehyde at greater than 25 ppm was eliminated due to NASA concerns with safety and toxicity and methyl isothiazolone was eliminated from further consideration due to ineffectiveness against biofilms and toxicity at higher concentrations.
Technical Paper

Crew Exploration Vehicle (CEV) Potable Water System Verification Coordination

2008-06-29
2008-01-2083
The Crew Exploration Vehicle (CEV), also known as Orion, will ferry a crew of up to six astronauts to the International Space Station (ISS), or a crew of up to four astronauts to the moon. The first launch of CEV is scheduled for approximately 2014. A stored water system on the CEV will supply the crew with potable water for various purposes: drinking and food rehydration, hygiene, medical needs, sublimation, and various contingency situations. The current baseline biocide for the stored water system is ionic silver, similar in composition to the biocide used to maintain quality of the water transferred from the Orbiter to the ISS and stored in Contingency Water Containers (CWCs). In the CEV water system, the ionic silver biocide is expected to be depleted from solution due to ionic silver plating onto the surfaces of the materials within the CEV water system, thus negating its effectiveness as a biocide.
Technical Paper

Extravehicular Mobility Unit (EMU)/International Space Station (ISS) Coolant Loop Failure and Recovery

2006-07-17
2006-01-2240
Following the Colombia accident, the Extravehicular Mobility Units (EMU) onboard ISS were unused for several months. Upon startup, the units experienced a failure in the coolant system. This failure resulted in the loss of Extravehicular Activity (EVA) capability from the US segment of ISS. With limited on-orbit evidence, a team of chemists, engineers, metallurgists, and microbiologists were able to identify the cause of the failure and develop recovery hardware and procedures. As a result of this work, the ISS crew regained the capability to perform EVAs from the US segment of the ISS Figure 1.
Technical Paper

Selection of an Alternate Biocide for the ISS Internal Thermal Control System Coolant - Phase II

2004-07-19
2004-01-2472
The ISS (International Space Station) ITCS (Internal Thermal Control System) includes two internal coolant loops that utilize an aqueous based coolant for heat transfer. A silver salt biocide had previously been utilized as an additive in the coolant formulation to control the growth and proliferation of microorganisms within the coolant loops. Ground-based and in-flight testing demonstrated that the silver salt was rapidly depleted, and did not act as an effective long-term biocide. Efforts to select an optimal alternate biocide for the ITCS coolant application have been underway and are now in the final stages. An extensive evaluation of biocides was conducted to down-select to several candidates for test trials and was reported on previously.
Technical Paper

Selection of an Alternate Biocide for the International Space Station Internal Active Thermal Control System Coolant Loops

2003-07-07
2003-01-2568
The International Space Station (ISS) IATCS (Internal Active Thermal Control System) includes two internal coolant loops that use an aqueous based coolant for heat transfer. A silver salt biocide was used initially as an additive in the coolant formulation to control the growth and proliferation of microorganisms in the coolant loops. Ground-based and in-flight testing has demonstrated that the silver salt is rapidly depleted and not effective as a long-term biocide. Efforts are now underway to select an alternate biocide for the IATCS coolant loop with greatly improved performance. An extensive evaluation of biocides was conducted to select several candidates for test trials.
Technical Paper

Testing of Russian ECLSS - Sabatier and Potable Water Processor

1994-06-01
941252
Hamilton Standard Space Systems International, Inc. (HSSSI) has obtained and is currently testing a variety of Russian life support hardware. These units have been or are contemplated for use on Mir I and II space stations. This paper presents the current status of performance testing of a Sabatier Carbon Dioxide Processing Unit (CDPU) and components of a Potable Water Processing System (PWP). These systems were fabricated by NIICHIMMASH, the supplier of these units to the Russian space program. It is the intent of this testing program to obtain a data base for technology comparisons to support planned and future international missions. For the CDPU, reactant conversion efficiencies in excess of 99 percent have been noted for the variation in test conditions with 2 to 6 man processing (flows) tested. The CDPU's effluent water has been produced at anticipated rates and is relatively contaminant free.
Technical Paper

Condensing Heat Exchanger Microbial Growth and Control Study-Phase II

1993-07-01
932107
The Space Station Temperature and Humidity Control Condensing Heat Exchangers will be utilized to collect and remove atmospheric water vapor generated by the metabolic and hygienic activity of crew members. The porous hydrophilic coating within the heat exchangers will always be wet. Cabin air will continuously flow through the heat exchangers during system operation which makes them a potential site for microbial colonization. This paper summarizes the findings from an ongoing study which evaluates biofilm formation on wet hydrophilic coated panels compared to panels to which microbial control measures have been applied. The control measures evaluated are an antimicrobial agent within the coating and periodic drying.
X