Technical Paper

Comparative Evaluation of the Q3 and Hybrid Iii 3-Year-Old Dummies in Biofidelity and Static Out-Of-Position Airbag Tests

2000-11-01
2000-01-SC03
A comparison of the Q3 and Hybrid III 3-year-old crash test dummies is presented in this paper. The performance of the dummies were compared in sixty biofidelity tests, seventy-seven static out-of-position airbag tests and sixty- three calibration tests. Various time histories and other data pertaining to accelerations, deflections, forces and moments are compared. In addition, the ease of positioning, handling, and the durability of the dummies in various out- of-position test configurations was assessed. Both the Q3 and Hybrid III 3-year-old dummies were calibrated to their respective specifications. The Hybrid III 3-year-old met its calibration requirements, while the Q3 did not always meet its own calibration requirements. The calibration specifications of the Q3 dummy need to be re-examined and possibly refined. The biofidelity of the Q3 and Hybrid III 3-year-old dummies were evaluated in both frontal and lateral test modes.
Technical Paper

SID-IIs Beta+-Prototype Dummy Biomechanical Responses

1998-11-02
983151
This paper presents the results of biomechanical testing of the SID-IIs beta+-prototype dummy by the Occupant Safety Research Partnership. The purpose of this testing was to evaluate the dummy against its previously established biomechanical response corridors for its critical body regions. The response corridors were scaled from the 50th percentile adult male corridors defined in International Standards Organization Technical Report 9790 to corridors for a 5th percentile adult female, using established International Standards Organization procedures. Tests were performed for the head, neck, shoulder, thorax, abdomen and pelvis regions of the dummy. Testing included drop tests, pendulum impacts and sled tests. The biofidelity of the SID-IIs beta+-prototype was calculated using a weighted biomechanical test response procedure developed by the International Standards Organization.
X