Technical Paper

Open Path Fourier Transform Infrared (OP-FTIR) Spectrometry as a Multi-Analyte Sensor for Spacecraft Air

1998-07-13
981567
Open-path Fourier transform infrared (OP-FTIR) spectrometry was evaluated for potential application to the measurement of contaminants in spacecraft air environments. OP-FTIR provides simultaneous, real-time quantification and confirmation of identity for most contaminants on the current Spacecraft Maximum Allowable Concentration (SMAC) list. In addition, the open-path measurement configuration provides characterization of an area rather than at a point. The dynamic composition and distribution of air contaminants throughout spacecraft air systems is measured without the need for multi-point sampling. These characteristics of open path FTIR make it a valuable method for spacecraft air characterization.
Technical Paper

Air Quality Monitoring by Open Path Fourier Transform Infrared (FTIR) Spectrometry

1997-07-01
972391
The feasibility of using open path Fourier transform infrared (OP-FTIR) spectrometry as an ambient air sensor on spacecraft was examined. OP-FTIR is a valuable monitoring technique because the sensor requires no sample preparation or separations and compositional information obtained is along a path rather than at a sampling point. OP-FTIR monitors and quantitates in real-time, offers high sensitivity, and detection is compound-specific. The data analysis, data reduction, and hardware requirements were investigated and potential applicability of chemometric methods and state-of-the-art commercial hardware systems were discussed.
Technical Paper

Development of a Portable Contamination Detector for Use During EVA

1991-07-01
911387
Initial efforts in the development of an EVA portable contamination detector (EVA PCD) for use by the EVA crew have resulted in the selection and preliminary testing of a concept based upon time-of-flight(TOF) mass spectrometry. The EVA PCD will be a compact, man-portable device intended for use in the ambient vacuum outside the Space Station. It will be used to monitor the surfaces of the EVA suits and mobility units for the presence of potentially toxic contaminants, such as hydrazine propellants and oxidizers, which might otherwise be inadvertently carried into the interior of the Station. The EVA PCD will also be used to locate small leaks of heat exchange fluids in the outer surface of the Station. This paper describes some key performance needs for the EVA PCD system, approaches taken to interpreting those needs, and some of the results of tradeoff analyses which led to the selection of the TOF concept. Some results from initial experimental tests of a TOF unit are presented.
Technical Paper

The Development of a Volatile Organics Concentrator for Use in Monitoring Space Station Water Quality

1991-07-01
911435
An approach to the isolation and concentration of volatile organic compounds from a water sample prior to chemical analysis in a microgravity environment has been previously described (Reference 1). The Volatile Organics Concentrator (VOC) system was designed for attachment to a gas chromatograph/mass spectrometer (GC/MS) for analysis of the volatile organics in water on Space Station Freedom. The VOC concept utilizes a primary solid sorbent for collection and concentration of the the organics from water, with subsequent transfer using nitrogen gas through a permeation dryer tube to a secondary solid sorbent tube. The secondary solid sorbent is thermally desorbed to a gas chromatograph for separation of the volatiles which are detected using a mass spectrometer.
Technical Paper

A Volatile Organics Concentrator for Use in Monitoring Space Station Water Quality

1990-07-01
901352
The process used to identify, select and design an approach to the isolation and concentration of volatile organic compounds from a water sample prior to chemical analysis in a microgravity environment is described. The Volatile Organics Concentrator (VOC) system described in this paper has been designed for attachment to a gas chromatograph/mass spectrometer (GC/MS) for analysis of volatile organics in water on Space Station. In this work, in order to rank the many identified approaches, the system was broken into three critical areas. These were gases, volatile separation from water and water removal/GC/MS interface. Five options involving different gases (or combinations) for potential use in the VOC and GC/MS system were identified and ranked. Nine options for separation of volatiles from the water phase were identified and ranked. Seven options for use in the water removal/GC column and MS interface were also identified and included in overall considerations.