Refine Your Search

Search Results

Author:
Viewing 1 to 4 of 4
Technical Paper

Development of a Low Cost Cascade Aerodynamics Test Facility Using a Simple Flow Visualization Velocimetry Technique

2002-04-16
2002-01-1543
A unique cascade test facility has been developed for use in the Wichita State University (WSU) water table. Although small in scale, the WSU water table has the advantage of low cost and the ease with which test conditions can be varied. Water table facilities have been used in the past for cascade experiments, especially as analogies for compressible flow visualization of turbine cascades. However, the lack of a quantitative measurement technique at low speeds has precluded the use of the water table as an analogy for testing subsonic compressors and turbines. In the present experiment, the hydrogen bubble flow visualization technique is used to generate bubble time lines, and a CCD (Charge Coupled Device) video camera system captures and digitizes these time line images. A VisualBASIC® computer program is then used to determine the wake velocity profile based on the difference in bubble line positions at successive intervals of time.
Technical Paper

Experimental Investigation of Gurney Flaps on Reflection Plane Wing with Fuselage and/or Nacelle

1997-05-01
971468
An experimental investigation on the effects of Gurney flaps on a reflection plane model was conducted. Two sizes of Gurney flaps were tested on a series of configurations which included a tapered wing (with a NLF-0215 airfoil section), a fuselage, a nacelle, and their permutations. The tests were conducted at a Reynolds number of 1.0 million based on mean chord. Results indicated that lift and drag were increased upon using the Gurney flaps; lift to drag and lift squared to drag ratios were also increased. In particular, the lift to drag ratio for the complete “airplane” was almost the same with or without a small Gurney flap. Pitching moment became more negative (nose-down) with the Gurney flap, and positive (nose-up) with the addition of the fuselage.
Technical Paper

The Effect of Gurney Flaps on Three-Dimensional Wings with and without Taper

1996-10-01
965514
The effect of Gurney flaps on three-dimensional wings was investigated in the 7x10 feet low speed wind tunnel. There have been a number of studies on Gurney flaps in recent years. However, these studies have been limited to two-dimensional airfoils. A comprehensive investigation on the effect of Gurney flaps for a wide range of configurations and test conditions was conducted at Wichita State University. In this part of the investigation, straight and tapered three-dimensional wings with Natural Laminar Flow (NLF) airfoil sections were tested. Gurney flaps spanning 4.5, 3.0, and 1.5 feet were tested on a straight NLF wing of 5 feet span. Compared to the clean wing, the 4.5 feet span 0.017c and 0.033c height Gurney flaps increased the maximum lift coefficient by 17% and 22%, respectively. The increase in maximum lift coefficient was proportionately smaller with the shorter span Gurney flaps.
Technical Paper

The Post-Stall Effect of Gurney Flaps on a NACA-0011 Airfoil

1996-05-01
961316
The effect of Gurney flaps on a NACA 0011 airfoil was investigated. Gurney flaps provide a substantial increase in lift while the penalty in drag is small. With the Gurney flap, the airfoil pressure distribution shows increased suction on the upper surface and higher pressure on the lower surface compared to the clean airfoil. This change in pressure is most profound on the lower surface just in front of the Gurney flap. Since separation occurs on the upper surface upon stall, this higher pressure condition on the lower surface continues into the post-stall regime. Thus, the NACA 0011 airfoil with Gurney flaps generates lift coefficients greater than one even under post-stall conditions.
X