Technical Paper
Development of Boiling Prediction Method in LP-EGR Cooler and Shape Optimization for Suppressing Boiling using Boiling Index
2021-04-06
2021-01-0228
An EGR system has been significantly used in order to cope with reinforced exhaust gas regulation and enhancement of fuel efficiency. For the well-designed EGR cooler, performance analysis is basically required. Furthermore, boiling prediction of the EGR cooler is especially essential to evaluate durability failure of abnormal operating conditions in DPF. However, due to intrinsic complexity of detailed 3-dimensional heat transfer tubes in the EGR cooler, no precise technique of boiling prediction has been developed. Therefore, this research had been performed in order to fulfill 3 goals: (1) development of 3-dimentional performance prediction technique including boiling occurrence, (2) generation and validation of a new evaluation index for boiling, (3) development of an optimized EGR cooler for suppressing boiling. In order to increase analysis accuracy and reduce analysis efforts at the same time, 3-dimensional single-phase flow analysis was developed.