Refine Your Search

Search Results

Author:
Viewing 1 to 14 of 14
Technical Paper

Kinematic and Injury Response of Reclined PMHS in Frontal Impacts

2021-04-02
2020-22-0004
Frontal impacts with reclined occupants are rare but severe, and they are anticipated to become more common with the introduction of vehicles with automated driving capabilities. Computational and physical human surrogates are needed to design and evaluate injury countermeasures for reclined occupants, but the validity of such surrogates in a reclined posture is unknown. Experiments with post-mortem human subjects (PMHS) in a recline posture are needed both to define biofidelity targets for other surrogates and to describe the biomechanical response of reclined occupants in restrained frontal impacts. The goal of this study was to evaluate the kinematic and injury response of reclined PMHS in 30 g, 50 km/h frontal sled tests. Five midsize adult male PMHS were tested. A simplified semi-rigid seat with an anti-submarining pan and a non-production three-point seatbelt (pre-tensioned, force-limited, seat-integrated) were used.
Technical Paper

Whole-Body Response to Pure Lateral Impact

2010-11-03
2010-22-0014
The objective of the current study was to provide a comprehensive characterization of human biomechanical response to whole-body, lateral impact. Three approximately 50th-percentile adult male PMHS were subjected to right-side pure lateral impacts at 4.3 ± 0.1 m/s using a rigid wall mounted to a rail-mounted sled. Each subject was positioned on a rigid seat and held stationary by a system of tethers until immediately prior to being impacted by the moving wall with 100 mm pelvic offset. Displacement data were obtained using an optoelectronic stereophotogrammetric system that was used to track the 3D motions of the impacting wall sled; seat sled, and reflective targets secured to the head, spine, extremities, ribcage, and shoulder complex of each subject. Kinematic data were also recorded using 3-axis accelerometer cubes secured to the head, pelvis, and spine at the levels of T1, T6, T11, and L3. Chest deformation in the transverse plane was recorded using a single chestband.
Technical Paper

Impact Response of Restrained PMHS in Frontal Sled Tests: Skeletal Deformation Patterns Under Seat Belt Loading

2009-11-02
2009-22-0001
This study evaluated the response of restrained post-mortem human subjects (PMHS) in 40 km/h frontal sled tests. Eight male PMHS were restrained on a rigid planar seat by a custom 3-point shoulder and lap belt. A video motion tracking system measured three-dimensional trajectories of multiple skeletal sites on the torso allowing quantification of ribcage deformation. Anterior and superior displacement of the lower ribcage may have contributed to sternal fractures occurring early in the event, at displacement levels below those typically considered injurious, suggesting that fracture risk is not fully described by traditional definitions of chest deformation. The methodology presented here produced novel kinematic data that will be useful in developing biofidelic human models.
Technical Paper

Internal vs. External Chest Deformation Response to Shoulder Belt Loading, Part 1: Table-Top Tests

2009-04-20
2009-01-0393
This study presents a detailed comparison of internally and externally measured chest deflections resulting from eight tests conducted on three male post mortem human subjects. A hydraulically driven shoulder belt loaded the anterior thorax under a fixed spine condition while displacement data were obtained via a high-speed 16-camera motion capture system (VICON MX™). Comparison of belt displacement and sternal displacement measured at the bone surface provided a method for quantifying effective change in superficial soft tissue depth at the mid sternum under belt loading. The relationship between the external displacement and the decrease in the effective superficial tissue depth was found to be monotonic and nonlinear. At 65 mm of mid-sternal posterior displacement measured externally, the effective thickness of the superficial tissues and air gap between the belt and the skin had decreased by 14 mm relative to the unloaded state.
Technical Paper

Elimination of Thoracic Muscle Tensing Effects for Frontal Crash Dummies

2005-04-11
2005-01-0307
Current crash dummy biofidelity standards include the estimated effects of tensing the muscles of the thorax. This study reviewed the decision to incorporate muscle tensing by examining relevant past studies and by using an existing mathematical model of thoracic impacts. The study finds evidence that muscle tensing effects are less pronounced than implied by the biofidelity standard response corridors, that the response corridors were improperly modified to include tensing effects, and that tensing of other body regions, such as extremity bracing, may have a much greater effect on the response and injury potential than tensing of only the thoracic musculature. Based on these findings, it is recommended that muscle tensing should be eliminated from thoracic biofidelity requirements until there is sufficient information regarding multi-region muscle tensing response and the capability to incorporate this new data into a crash dummy.
Technical Paper

Assessment of the Thor and Hybrid III Crash Dummies: Steering Wheel Rim Impacts to the Upper Abdomen

2004-03-08
2004-01-0310
This investigation explored THOR's force-deflection response to upper abdomen/lower ribcage steering wheel rim impacts in comparison to the Hybrid III and cadaver test subjects. The stationary subjects were impacted by a ballasted surrogate wheel propelled at 4 m/s, a test condition designed to approximate the upper abdomen impacting a steering wheel rim in a frontal crash. Both the standard THOR and the Hybrid III crash dummies were substantially stiffer than the cadavers. Removing THOR's torso skin and foam from the upper abdomen and replacing the standard Hybrid III abdomen with a prototype gel-filled unit produced force-deflection results that were more similar to the cadavers. THOR offers advantages over the Hybrid III because of its ability to measure abdominal deflection. THOR, with modification, would be a useful instrument with which to assess the crashworthiness of steering assemblies and restraint systems in frontal crashes.
Technical Paper

A Normalization Technique for Developing Corridors from Individual Subject Responses

2004-03-08
2004-01-0288
This paper presents a technique for developing corridors from individual subject responses contained in experimental biomechanical data sets. Force-deflection response is used as an illustrative example. The technique begins with a method for averaging human subject force-deflection responses in which curve shape characteristics are maintained and discontinuities are avoided. Individual responses sharing a common characteristic shape are averaged based upon normalized deflection values. The normalized average response is then scaled to represent the given data set using the mean peak deflection value associated with the set of experimental data. Finally, a procedure for developing a corridor around the scaled normalized average response is presented using standard deviation calculations for both force and deflection.
Technical Paper

The Utility of Hybrid III and THOR Chest Deflection for Discriminating Between Standard and Force-Limiting Belt Systems

2003-10-27
2003-22-0013
Recent field data studies have shown that force-limiting belt systems reduce the occurrence of thoracic injuries in frontal crashes relative to standard (not force-limiting) belt systems. Laboratory cadaver tests have also shown reductions in trauma, as well as in chest deflection, associated with a force-limiting belt. On the other hand, tests using anthropomorphic test devices (ATDs) have shown trends indicating increased, decreased, or unchanged chest deflection. This paper attempts to resolve previous experimental studies by comparing the anterior-posterior and lateral chest deflections measured by the THOR and Hybrid III (H-III) dummies over a range of experimental conditions. The analysis involves nineteen 48-km/h and 57-km/h sled tests utilizing force-limiting and standard seat belt systems, both with an air bag. Tests on both the driver side and the passenger side are considered.
Technical Paper

Response of the Thor-Lx and Hybrid III Lower Extremities in Frontal Sled Tests

2003-03-03
2003-01-0161
The objectives of this study were to evaluate and compare the responses, repeatability, and durability of the Thor-Lx/HIIIr and Hybrid III/Denton lower extremities in frontal sled tests. Effectiveness of the two limb types was studied by evaluating responses in different test configurations using existing and proposed Injury Assessment Reference Values (IARVs) for both leg designs. Hybrid III or Thor-Lx legs were attached to the distal femurs of a 50th percentile male Hybrid III dummy, which was subjected to three series of 56 km/h frontal sled tests with and without toepan intrusion. Due to the design differences, many of the absolute response values were different between the Hybrid III and Thor-Lx legs. The expanded measurement capabilities, modified geometry and refined responses of the Thor-Lx limbs provide a more thorough and conservative judgment of injury risk.
Technical Paper

Comparison of Belted Hybrid III, THOR, and Cadaver Thoracic Responses in Oblique Frontal and Full Frontal Sled Tests

2003-03-03
2003-01-0160
This paper compares restrained Hybrid III and THOR thoracic kinematics and cadaver injury outcome in 30° oblique frontal and in full frontal sled tests. Peak shoulder belt tension, the primary source of chest loading, changed by less than four percent and peak chest resultant acceleration changed by less than 10% over the 30° range tested. Thoracic kinematics were likewise insensitive to the direction of the collision vector, though they were markedly different between the two dummies. Mid-sternal Hybrid III chest deflection, measured by the standard sternal potentiometer and by supplemental internal string potentiometers, was slightly lower (∼10%) in the oblique tests, but the oblique tests produced a negligible increase in lateral movement of the sternum. In an attempt to understand the biofidelity of these dummy responses, a series of 30-km/h human cadaver tests having several collision vectors (0°, 15°, 30°, 45°) was analyzed.
Technical Paper

Comparative Evaluation of Dummy Response with Thor-Lx/HIIIr and Hybrid III Lower Extremities

2002-03-04
2002-01-0016
Multiple series of frontal sled tests were performed to evaluate the new Thor-Lx/HIIIr lower extremity developed by the National Highway Traffic Safety Administration for retrofit use on the 50th percentile male Hybrid III. This study's objective was to compare the Thor-Lx/HIIIr to the existing Hybrid III dummy leg (HIII) from the standpoint of repeatability and effects on femur and upper body response values.\ The test-to-test repeatability of the dummy responses, as measured by the coefficient of variation (CV), was generally acceptable (CV < 10%) for all of the test conditions for both legs. Overall, tests with the Thor-Lx/HIIIr legs produced upper body movement and injury criteria values for the head and chest that were acceptably consistent and were generally indistinguishable from those produced with the HIII leg. Low right femur loads, which ranged from 4 to 25 percent of the injury assessment reference value, varied substantially test-to-test for tests with both types of legs.
Technical Paper

Displacement Measurements in the Hybrid III Chest

2001-03-05
2001-01-0118
This paper presents an analysis of the displacement measurement of the Hybrid III 50th percentile male dummy chest in quasistatic and dynamic loading environments. In this dummy, the sternal chest deformation is typically characterized using a sliding chest potentiometer, originally designed to measure inward deflection in the central axis of the dummy chest. Loading environments that include other modes of deformation, such as lateral translations or rotations, can create a displacement vector that is not aligned with this sensitive axis. To demonstrate this, the dummy chest was loaded quasistatically and dynamically in a series of tests. A string potentiometer array, with the capability to monitor additional deflection modes, was used to supplement the measurement of the chest slider.
Technical Paper

Reducing the Risk of Driver Injury from Common Steering Control Devices in Frontal Collisions

1999-03-01
1999-01-0759
Steering control devices are used by people who have difficulty gripping the steering wheel. These devices have projections that may extend up to 14 cm toward the occupant. Testing indicated that contact with certain larger steering control devices with tall rigid projections could severely injure a driver in a frontal collision. In order to reduce this injury risk, an alternative, less injurious design was developed and tested. This design, which included replacing unyielding aluminum projections with compliant plastic ones, produced significantly lower peak contact pressure and less damage to the chest of a cadaver test subject, while maintaining the strength necessary to be useful.
Technical Paper

Interlaboratory Study of Proposed Compliance Test Protocol for Wheelchair Tiedown and Occupant Restraint Systems

1994-11-01
942229
To provide effective occupant protection for people who ride in motor vehicles while seated in wheelchairs, products are required that both secure the wheelchair and restrain the occupant. An international effort to develop dynamic test standards for these products has produced a compliance test protocol that includes specification of the sled deceleration-time history, the crash pulse corridor. An interlaboratory study was conducted to determine if the crash pulse corridor was sufficiently defined to produce acceptably low variation in the test results. The study, that involved four labs each replicating the same sled test three times, produced consistent results. The study results suggest that a reasonably precise compliance test protocol can be defined using a crash pulse corridor that is generously drawn to accommodate rather large differences in sled crash pulse shapes.
X