Refine Your Search

Search Results

Technical Paper

The Biofidelity of EUROSID 1 and BIOSID

1992-11-01
922518
A current priority in Europe and the USA is the development of improved side collision dummies. This report presents the results of sled tests with three test subject types: cadavers (PMHS), EUROSID 1 and BIOSID. Twenty one (21) cadaver tests were performed and 9 dummy tests a piece. The left side of the test subjects were impacted under one of two different test conditions: 24 km/h rigid wall and 32 km/h padded wall. The cadavers were instrumented with a 12 thoracic, and triaxial pelvic accelerometer arrays. Thoracic deformation was calculated from rib accelerations. The dummies were instrumented in their standard formats, which included the ability to measure coronal plane thoracic deformation. For all test subject types and measurement locations the 3ms. acceleration standard deviations were low. Mean 3ms. accelerations showed no consistent relationship in magnitude between subject types. The measured dummy rib deformations were compared to the calculated cadaver deformations.
X