Journal Article

Thermal Load Reduction of Truck Tractor Sleeper Cabins

2008-10-07
2008-01-2618
Several configurations of truck tractor sleeper cabs were tested and modeled to investigate the potential to reduce heating and cooling loads. Two trucks were tested outdoors and a third was used as a control. Data from the testing were used to validate a computational fluid dynamics (CFD) model and this model was used to predict reductions in cooling loads during daytime rest periods. The test configurations included the application of standard-equipped sleeper privacy curtain and window shades, an optional insulated or arctic sleeper curtain, and insulated window coverings. The standard curtain reduced sleeper area heating load by 21% in one test truck, while the arctic curtain decreased it by 26%. Insulated window coverings reduced the heating load by 16% in the other test truck and lowered daytime solar temperature gain by 8°C. The lowered temperature resulted in a predicted 34% reduction in cooling load from the model.
X