Refine Your Search

Search Results

Viewing 1 to 2 of 2
Technical Paper

Closed-Loop Air-Fuel Ratio Control Using Forced Air-Fuel Ratio Modulation

1998-02-23
980041
An air-to-fuel ratio (A/F) modulation scheme is presented in which a linear feedback signal is generated from a heated exhaust gas oxygen (EGO) sensor. In this scheme, the engine A/F is modulated with a triangular waveform, and the mean value of the EGO output is obtained using a rolling average filter. The resulting output is linearly related to the exhaust A/F, and is used to provide closed-loop lean A/F operation following a cold start to enhance catalyst light-off and minimize vehicle exhaust emissions. Some engine-dynamometer results obtained using the method are presented.
Technical Paper

A Closed-Loop A/F Control Model for Internal Combustion Engines

1980-06-01
800826
A mathematical model is developed which describes the operation of an A/F control system containing an engine, an exhaust gas oxygen sensor, and a feedback controller. The dependence of model parameters on engine operating conditions is discussed, and the model is used to compare integral and proportional/integral control algorithms. Actual data obtained on an engine-dynamometer are presented to test the validity of the model.