Measurement of Co-efficient of Thermal Expansion of CFRP Strut for IRS-1C Spacecraft

1994-06-01
941470
The measurement of coefficient of thermal expansion of CFRP strut which is planned to be used in Indian Remote Sensing Spacecraft (IRS-1C) has been measured from -10°C to +50°C using an electronic digital indicator. A suitable test rig was designed and fabricated to carry out this measurement in the required temperature range. The coefficient of the thermal expansion results obtained with this testing and technique are accurate to ± 13.4% and the repeatability of this measurement is better than ± 1.3%.
Technical Paper

Experimental Evaluation of Copper Braid Thermal Conductance for IRS-1C Spacecraft

1994-06-01
941471
“Tinned Copper Braid” is planned to be used in IRS-1C spacecraft for the thermal control of the detector of the “Middle Infra Red” (MIR) band of LISS III Camera. The thermal conductance of the braid was evaluated experimentally in the temperature range of -65°C to +35°C by employing the calorimetric technique. The measured thermal conductance of the 215mm long copper braid varies from 0.051 to 0.056 W/°C at different temperatures in the specified range. An error estimation has been performed which shows a maximum uncertainty of better than ± 5% on the conductance value measured.