Development of a Heat Switch for Use 20-50K

1994-06-01
941530
If a cryocooler connected to an instrument fails there is a parasitic load on the instrument due to conduction down the cold finger. In normal operation the cryocooler provides enough cooling to absorb this parasitic load in addition to the cooling required for the instrument. If multiple coolers are used on an instrument it is helpful if the failed cooler can be thermally disconnected to reduce the thermal load on the remaining coolers. Also, it may be a requirement that a “spare” redundant cooler be thermally connected to the instrument to provide cooling in place of a failed cooler. For both of these operations some type of thermal switch is required. The design and development of such a switch is described in this paper. When two metal surfaces are pressed together the contact between them is on the tips of irregularities on their surfaces; these asperities are plastically deformed as the load increases so that the area of contact is proportional to the load.