Refine Your Search

Search Results

Viewing 1 to 4 of 4
Technical Paper

Posterior Cruciate Ligament Response to Proximal Tibia Impact

2019-04-02
2019-01-1221
Posterior cruciate ligament (PCL) injuries, although rarely life threatening, affect the quality of life of the person who sustains the injury. The PCL is the primary restraint to posterior tibial translation and can be injured when the tibia moves posteriorly relative to the femur. This type of injury is common in frontal crashes where the tibia may impact the dashboard or steering column. To quantify what happens during dynamic loading of the tibial plateau, isolated cadaveric lower limbs (n = 14) were impacted at dynamic rates with a linear pneumatic ram. During the testing, a static load was applied to the quadriceps tendon to simulate active musculature. Forces as well as the stretch of the PCL were measured. The most common injuries were tibia fractures and PCL tears. The stiffness for the tests at impact velocities of 1.4 and 2.9 m/s were on average 120 N/mm and 141N/mm, respectively. A trend towards increasing femur force with increasing velocity was found.
Technical Paper

Evaluation of the Internal and External Biofidelity of Current Rear Impact ATDs to Response Targets Developed from Moderate-Speed Rear Impacts of PMHS

2012-10-29
2012-22-0005
The goal of this study is to evaluate both the internal and external biofidelity of existing rear impact anthropomorphic test devices (BioRID II, RID3D, Hybrid III 50th) in two moderate-speed rear impact sled test conditions (8.5g, 17 km/h; 10.5g, 24 km/h) by quantitatively comparing the ATD responses to biomechanical response targets developed from PMHS testing in a corresponding study. The ATDs and PMHS were tested in an experimental seat system that is capable of simulating the dynamic seat back rotation response of production seats. The experimental seat contains a total of fourteen load cells installed such that external loads from the ATDs and PMHS can be measured to evaluate external biofidelity. The PMHS were instrumented to correspond to the instrumentation contained in the ATDs so that direct comparison between ATDs and PMHS could be made to evaluate internal biofidelity.
Technical Paper

Biomechanical Responses of PMHS in Moderate-Speed Rear Impacts and Development of Response Targets for Evaluating the Internal and External Biofidelity of ATDs

2012-10-29
2012-22-0004
The objectives of this study were to obtain biomechanical responses of post mortem human subjects (PMHS) by subjecting them to two moderate-speed rear impact sled test conditions (8.5g, 17 km/h; 10.5g, 24 km/h) while positioned in an experimental seat system, and to create biomechanical targets for internal and external biofidelity evaluation of rear impact ATDs. The experimental seat was designed to measure external loads on the head restraint (4 load cells), seat back (6 load cells), and seat pan (4 load cells) such that subject dynamic interaction with the seat could be evaluated. This seat system was capable of simulating the dynamic characteristics of modern vehicle seat backs by considering the moment-rotation properties of a typical passenger vehicle, thus providing a more realistic test environment than using a rigid seat with a non-rotating seat back as done in previous studies.
Technical Paper

Pressure-Based Abdominal Injury Criteria Using Isolated Liver and Full-Body Post-Mortem Human Subject Impact Tests

2011-11-07
2011-22-0012
Liver trauma research suggests that rapidly increasing internal pressure plays a role in liver injury. Previous work has shown a correlation between pressure and liver injury in pressurized ex vivo human livers when subjected to blunt impacts. The purpose of this study was to extend the investigation of this relationship between pressure and liver injury by testing full-body post-mortem human surrogates (PMHS). Pressure-related variables were compared with one another and also to previously proposed biomechanical predictors of abdominal injury. Ten PMHS were tested. The abdominal vessels were pressurized to physiological levels using saline, and a pneumatic ram impacted the right side of the specimen ribcage at a nominal velocity of 7.0 m/s. Specimens were subjected to either lateral (n = 5) or oblique (n = 5) impacts, and the impact-induced pressures were measured by transducers inserted into the hepatic veins and inferior vena cava.
X