Refine Your Search

Search Results

Author:
Viewing 1 to 6 of 6
Technical Paper

The Role of the Electrodes for the Ionization Sensor Signal

2003-03-03
2003-01-0714
The effect of the electrodes on the early signal of the ionization sensor has been studied experimentally and with a model for the sensor. Experiments in a constant-volume combustion chamber with a generic electrode configuration allowed to investigate the role of electrode contact and the main path of the current. A framework for a model allowing the inclusion of electrode processes is introduced, and a first implementation of this model is presented. The results from the simulations are in good qualitative agreement with the experimental observations. Our conclusion is that electrode processes can limit the current during early combustion, and that the geometry of the electrodes, and especially the cathode, govern the characteristic shape of the first current peak.
Technical Paper

Analysis of the Ionization Equilibrium in the Post-Flame Zone

2003-03-03
2003-01-0715
A combined experimental and theoretical effort has been made to identify the most important contributors to equilibrium ionization in the post-flame gas. In the past, nitric oxide (NO) has always been assumed to be the main electron donor in the compressed hot post-flame gases. However, correlations observed between the amount of NO in the exhaust gases and the current amplitude may be deceiving due to the fact that both the formation of NO and the ionization process are strongly temperature dependend. The temperature-current relationship in data from various experiments in constant volume combustion chambers and engines was utilized to check the hypothesis that NO acts as the major contributor to ionization. Based on a well-motivated model for the current, the effect of temperature and electron donor concentration has been separated.
Technical Paper

The Effect of In-Cylinder Gas Flow on the Interpretation of the Ionization Sensor Signal

2003-03-03
2003-01-1120
The location of the peak pressure can serve as a control parameter to adjust ignition timing and optimize engine performance. The ionization sensor, an electrical probe for combustion diagnostics, can provide information about the peak pressure location. However, the reliability of such information is rather poor. In-cylinder gas flow at the electrodes may be one reason for this. We present results from an investigation of the relationship between ionization sensor current and pressure under various gas flow conditions. The gas flow velocity in the vicinity of the electrode gap was measured by LDA. From the results one may infer how the in-cylinder gas flow affects the reliability of the prediction of pressure peak location from the ionization sensor signal. One finding is that high bulk gas flow impairs the precision of the prediction in certain configurations.
Technical Paper

Employing an Ionization Sensor for Combustion Diagnostics in a Lean Burn Natural Gas Engine

2001-03-05
2001-01-0992
An ionization sensor has been used to study the combustion process in a six-cylinder lean burn, truck-sized engine fueled with natural gas and optimized for low emissions of nitric oxides. The final goal of the investigations is to study the prospects of using the ionization sensor for finding the optimal operating position with respect to low NOx emission and stable engine operation. The results indicate that unstable combustion can be detected by analyzing the coefficient of variation (CoV) of the detector current amplitude. Close relationships between this measure and the CoV of the indicated mean effective pressure have been found during an air-fuel ratio scan with fixed ignition advance.
Technical Paper

Calorimetric Characterization of Commercial Ignition Systems

2000-03-06
2000-01-0548
The spark energy delivered to the gas has been measured calorimetrically for five different ignition systems at six pressure points. Both inductive and capacitive systems have been investigated. Simultaneous electrical measurements were used to estimate the fraction of electrically stored energy actually deposited in the gas time-resolved for two systems. A separation of breakdown and glow energy was attempted using a simple model for the heat distributed to the gas and the electrodes by the spark. The results are considered valuable for the understanding of spark energy deposition as well as the design of adaptable ignition systems.
Technical Paper

A Study of the Homogeneous Charge Compression Ignition Combustion Process by Chemiluminescence Imaging

1999-10-25
1999-01-3680
An experimental study of the Homogeneous Charge Compression Ignition (HCCI) combustion process has been conducted by using chemiluminescence imaging. The major intent was to characterize the flame structure and its transient behavior. To achieve this, time resolved images of the naturally emitted light were taken. Emitted light was studied by recording its spectral content and applying different filters to isolate species like OH and CH. Imaging was enabled by a truck-sized engine modified for optical access. An intensified digital camera was used for the imaging. Some imaging was done using a streak-camera, capable of taking eight arbitrarily spaced pictures during a single cycle, thus visualizing the progress of the combustion process. All imaging was done with similar operating conditions and a mixture of n-heptane and iso-octane was used as fuel. Some 20 crank angles before Top Dead Center (TDC), cool flames were found to exist.
X