Technical Paper

Biomechanical Responses and Injury Assessment of Post Mortem Human Subjects in Various Rear-facing Seating Configurations

2021-04-02
2020-22-0005
The objective of this study was to generate biomechanical corridors from post-mortem human subjects (PMHS) in two different seatback recline angles in 56 km/h sled tests simulating a rear-facing occupant during a frontal vehicle impact. PMHS were placed in a production seat which included an integrated seat belt. To achieve a repeatable configuration, the seat was rigidized in the rearward direction using a reinforcing frame that allowed for adjustability in both seatback recline angle and head restraint position. The frame contained instrumentation to measure occupant loads applied to the head restraint and seatback. To measure PMHS kinematics, the head, spine, pelvis, and lower extremities were instrumented with accelerometers and angular rate sensors. Strain gages were attached to anterior and posterior aspects of the ribs, as well as the mid-shaft of the femora and tibiae, to determine fracture timing. A chestband was installed at the mid sternum to quantify chest deformation.
Technical Paper

A Novel Approach to Scaling Age-, Sex-, and Body Size-Dependent Thoracic Responses using Structural Properties of Human Ribs

2020-03-31
2019-22-0013
Thoracic injuries are frequently observed in motor vehicle crashes, and rib fractures are the most common of those injuries. Thoracic response targets have previously been developed from data obtained from post-mortem human subject (PMHS) tests in frontal loading conditions, most commonly of mid-size males. Traditional scaling methods are employed to identify differences in thoracic response for various demographic groups, but it is often unknown if these applications are appropriate, especially considering the limited number of tested PMHS from which those scaling factors originate. Therefore, the objective of this study was to establish a new scaling approach for generating age-, sex-, and body size-dependent thoracic responses utilizing structural properties of human ribs from direct testing of various demographics.
Technical Paper

Sources of Variability in Structural Bending Response of Pediatric and Adult Human Ribs in Dynamic Frontal Impacts

2018-11-12
2018-22-0004
Despite safety advances, thoracic injuries in motor vehicle crashes remain a significant source of morbidity and mortality, and rib fractures are the most prevalent of thoracic injuries. The objective of this study was to explore sources of variation in rib structural properties in order to identify sources of differential risk of rib fracture between vehicle occupants. A hierarchical model was employed to quantify the effects of demographic differences and rib geometry on structural properties including stiffness, force, displacement, and energy at failure and yield. Three-hundred forty-seven mid-level ribs from 182 individual anatomical donors were dynamically (~2 m/s) tested to failure in a simplified bending scenario mimicking a frontal thoracic impact. Individuals ranged in age from 4 - 108 years (mean 53 ± 23 years) and included 59 females and 123 males of diverse body sizes.
Technical Paper

Quantification of Skeletal and Soft Tissue Contributions to Thoracic Response in a Dynamic Frontal Loading Scenario

2018-11-12
2018-22-0005
Thoracic injuries continue to be a major health concern in motor vehicle crashes. Previous thoracic research has focused on 50th percentile males and utilized scaling techniques to apply results to different demographics. Individual rib testing offers the advantage of capturing demographic differences; however, understanding of rib properties in the context of the intact thorax is lacking. Therefore, the objective of this study was to obtain the data necessary to develop a transfer function between individual rib and thoracic response. A series of non-injurious frontal impacts were conducted on six PMHS, creating a loading environment commensurate to previously published individual rib testing. Each PMHS was tested in four tissue states: intact, intact with upper limbs removed, denuded, and eviscerated. Following eviscerated thoracic testing, eight individual mid-level ribs from each PMHS were removed and loaded to failure.
Technical Paper

Application of Scaled Deflection Injury Criteria to Two Small, Fragile Females in Side Impact Motor Vehicle Crashes

2018-04-03
2018-01-0542
Thoracic injury criteria have been previously developed to predict thoracic injury for vehicle occupants as a function of biomechanical response. Historically, biomechanical testing of post-mortem human surrogates (PMHS) for injury criteria development has primarily been focused on mid-sized males. Response targets and injury criteria for other demographics, including small females, have been determined by scaling values from mid-sized males. The objective of this study was to explore the applicability of scaled injury criteria to their representative population. Two PMHS were subjected to a side-impact loading condition which replicates a near-side, MDB-to-vehicle impact for the driver. This was accomplished using the Advanced Side Impact System, or ASIS, on a HYGE sled. The sled acceleration matched the acceleration profile of an impacted vehicle, while the four pneumatic cylinders of the ASIS produced realistic door intrusion.
Technical Paper

Evaluation of the Kinematic Responses and Potential Injury Mechanisms of the Jejunum during Seatbelt Loading

2015-11-09
2015-22-0009
High-speed biplane x-ray was used to research the kinematics of the small intestine in response to seatbelt loading. Six driver-side 3-point seatbelt simulations were conducted with the lap belt routed superior to the pelvis of six unembalmed human cadavers. Testing was conducted with each cadaver perfused, ventilated, and positioned in a fixed-back configuration with the spine angled 30° from the vertical axis. Four tests were conducted with the cadavers in an inverted position, and two tests were conducted with the cadavers upright. The jejunum was instrumented with radiopaque markers using a minimally-invasive, intraluminal approach without inducing preparation-related damage to the small intestine. Tests were conducted at a target peak lap belt speed of 3 m/s, resulting in peak lap belt loads ranging from 5.4-7.9 kN. Displacement of the radiopaque markers was recorded using high-speed x-ray from two perspectives.