Refine Your Search

Search Results

Technical Paper

U.S. Laboratory-A Payload Rack Thermal Systems

1993-07-01
932276
A U.S. Laboratory-A (U.S. Lab-A) payload rack has two primary thermal control systems designed for cooling payloads: a water cooling system and a distributed avionics air cooling system. This paper gives an overview of the rack-level thermal control systems available in a U.S.Lab-Arack. This paper also presents an analysis of the existing sensible payload heat removal capability of the laboratory module cooling system. In the U.S. Lab-A, all payload rack locations are configured as per the international Standard Payload Rack (ISPR) configuration. This paper begins with an overview of the ISPR with emphasis on the liquid and air cooling interfaces. An overview of both the liquid and air cooling systems is presented, showing general capability and limitations, payload rack flow control modes and optional payload rack thermal configurations. Performance data showing a sample overall system-level thermal energy balance is presented.