NO2/NOx Ratio and NH3 Storage Estimation of Automotive SCR Multi-Brick Systems

2017-03-28
2017-01-0972
Many control approaches for selective catalytic reduction (SCR) systems require knowledge of ammonia storage (NH3 storage) to dose urea accurately. Currently there are no technologies to directly measure internal NH3 storage in a vehicle, so it can only be inferred from hardware sensors located upstream, downstream, or in the catalyst. This paper describes an application of extended Kalman filter (EKF) state estimator used as a virtual sensor for urea injection control of a multi-brick aftertreatment system. The proposed estimator combines mean-value physics-based models of combined SCR and diesel particulate filter (SCR/DPF), SCR and clean-up catalyst (CUC). It uses hardware sensors at the inlet and outlet of the aftertreatment system, and includes no sensors between the catalysts. Performance of the proposed estimator was validated in simulations against a high-fidelity model of the aftertreatment system.