Investigation of a Dual HVAC MAC System with Three Row Ducts Using 1D Modeling

2017-03-28
2017-01-0164
In an automotive air-conditioning (AC) system, upfront prediction of the cabin cool down rate in the initial design stage will help in reducing the overall product development (PD) time. Vehicle having higher seating capacity will have higher thermal load and providing thermal comfort to all passengers uniformly is a challenging task for the automotive HVAC (Heating Ventilation and Air conditioning) industry. Dual HVAC unit is generally used to provide uniform cooling to a large cabin volume. One dimensional (1D) simulation is being extensively used to predict the HVAC performance during the initial stage of PD. The refrigerant loop with components such as compressor, condenser, TXV and evaporator was modeled. The complicated vehicle cabin including the glazing surfaces and enclosures were modeled as a three row duct system using 1D tool AMESim®. The material type, density, specific heat capacity and thermal conductivity of the material were specified.