Uncertainties in Emissions Measurements in a Partial Flow Sampling System
2015-01-14
2015-26-0096
This paper investigates experimental uncertainties associated with gaseous and particulate emissions measurements in a partial flow emissions sampling system developed and built at the Larson Transportation Institute of the Pennsylvania State University. A small fraction of the tail pipe exhaust is diluted with dilution air and passed through a cyclone to eliminate particles bigger than 2.5 microns. The diluted exhaust is then passed through a 47 mm Teflon filter for gravimetric measurement of Particulate Matter (PM). Mass flow controllers operating at 5Hz are used to control the flow rates of dilution air, diluted exhaust, and proportional flow of diluted exhaust into a Tedlar bag. An ultrasonic flow meter is used to measure flow rate of tail pipe exhaust. At the end of a test, the concentration of gaseous emissions in the bag, namely CO2, CO, HC, and NOx are measured using a bag emissions analyzer.