Sensor Fusion for Liquid Level Detection in Tanks Mounted on a Heavy Duty vehicle

2013-10-14
2013-01-2495
The upcoming European legislation for heavy duty vehicles, EuVI, includes rules on monitoring of urea consumption and urea tank volume. These new rules put new demands on the level sensing system monitoring the urea tank. The normal vehicle mounted liquid level sensing system today consists of a single, more or less vertically placed, sensor. When the vehicle is tilted the level of the fluid at the sensor position normally changes. This results in a measurement error in the calculated volume, as the volume is calculated based only on the information from the level sensor. The presented modeling studies investigate the feasibility of using sensor fusion to improve the accuracy of liquid volume estimation on a heavy duty truck. In the first study, the signals from multiple level sensors located in various liquid containing tanks on the truck are fused.