Measurement of Dry Soot and Particulate Matter from Two-Stroke and Four-Stroke Snowmobiles

2010-09-28
2010-32-0042
Recent increases in emissions regulations within the snowmobile industry have led to significant advancements in fuel, exhaust, and control systems on snowmobiles. However, particulate matter is currently an unregulated exhaust component of snowmobile engines. The measurement of dry soot as well as particulate matter from snowmobiles is the focus of this paper. Two industry-representative snowmobiles were chosen for this research which included a 2006 Yamaha Nytro carbureted four-stroke and a 2009 Ski-Doo MX-Z direct-injected two-stroke. Measurements for each snowmobile included gaseous emissions (CO₂, CO, NOx, O₂, and THC), particulate matter collected on quartz filters, and dry soot measured using an AVL Micro Soot Sensor. Each snowmobile was tested over the industry-standard five-mode emissions certification test cycle to determine the emissions, dry soot, and particulate matter levels from idle to wide open throttle (full-load).