Low Temperature Active Regeneration of Soot Using Hydrogen in a Multi-Channel Catalyzed DPF

2010-04-12
2010-01-0562
Diesel particulate filter (DPF) systems are being used to reduce the particulate matter emissions of diesel vehicles. The DPF should be regenerated after certain driving hours or distance to eliminate soot in the filter. The most widely used method is active regeneration with oxygen at 550~650°C. Fuel penalty occurs when the exhaust gas temperature is increased. The low temperature oxidation technique is needed to reduce fuel consumption. In this study, we found that hydrogen could be used to decrease the PM oxidation temperature significantly on a catalyzed DPF (CDPF). The oxidation characteristics of PM with hydrogen supplied to CDPF were studied using a partial flow system. The partial flow system was used to control temperature and a flow rate independently. The CDPF was coated with Pt/Al₂O₃ 25g/ft₃, and a multi-channel CDPF (MC CDPF) with a square cross section of 1.65 cm width and length of 10 cm was used.