Refine Your Search

Search Results

Viewing 1 to 2 of 2
Technical Paper

On-Road Evaluation of an Integrated SCR and Continuously Regenerating Trap Exhaust System

2012-04-16
2012-01-1088
Four-way, integrated, diesel emission control systems that combine selective catalytic reduction for NOx control with a continuously regenerating trap to remove diesel particulate matter were evaluated under real-world, on-road conditions. Tests were conducted using a semi-tractor with an emissions year 2000, 6-cylinder, 12 L, Volvo engine rated at 287 kW at 1800 rpm and 1964 N-m. The emission control system was certified for retrofit application on-highway trucks, model years 1994 through 2002, with 4-stroke, 186-373 kW (250-500 hp) heavy-duty diesel engines without exhaust gas recirculation. The evaluations were unique because the mobile laboratory platform enabled evaluation under real-world exhaust plume dilution conditions as opposed to laboratory dilution conditions. Real-time plume measurements for NOx, particle number concentration and size distribution were made and emission control performance was evaluated on-road.
Technical Paper

A New Instrument for Diesel Particulate Filter Functional Tests in Development and Quality Control Applications

2010-04-12
2010-01-0809
A new Diesel Particulate Generator (DPG) has been developed and commercialized for the automated testing of full-size, light duty Diesel Particulate Filters (DPFs). The system was optimized for filter development testing with a wide parameter range of relevant functional tests, and quality assurance testing where repeatability and rapid testing is important. A carefully designed Diesel-fuelled burner is combined with blowers to produce flows, temperatures and particulate matter (PM) that are representative of Diesel engines. The burner operates with continuous combustion of a Diesel fuel spray, with three-stage introduction of controlled airflows. Variation of these flows allows control of particulate generation independently of total gas flow and temperature (over a temperature and flow range). The system can generate stable PM at more than 20 g/h, or operate without PM formation so permitting preheating of a test filter.
X