Refine Your Search

Search Results

Author:
Viewing 1 to 4 of 4
Technical Paper

Modular Multilevel GaN Based Ultra-High Power Density Electric Power Conversion and Transmission on the Lunar Surface

2023-09-05
2023-01-1509
NASA’s Watts on the Moon Challenge is seeking solutions to transfer at least 1.065 kW power from a 120 V dc source to a 24-32 V dc load over a 3-km distance under the same environmental conditions as the Lunar surface (i.e., 77 K temperature and 1 mTorr pressure). The selected solution from the author’s team proposed utilizing two modular multilevel Gallium Nitride (GaN) based isolated dc-dc converters to connect the 120 V dc source with the 24-32 V dc load bank via 1.5 kV rated dc transmission lines. The modular multilevel converters feature frequency multiplication, high step-down voltage ratio and low device voltage stress. In the converters, GaN gate injection transistor (GaN GIT) and GaN High-Electron-Mobility Transistor (GaN HEMT) devices are chosen as switching devices, due to the merits of lower power loss, radiation hardness and ability to work under cryogenic and vacuum conditions.
Technical Paper

Three-Layered Design, Protection & Control of Lunar DC Microgrids Utilizing WBG-Based Flexible DC Energy Router

2023-09-05
2023-01-1505
The reliable operation of power systems on the lunar surface is crucial for critical research activities and supporting life. These systems are standalone or interconnected grids that integrate intermittent power sources and distributed energy storage. Lunar microgrids must be highly reliable, reconfigurable, and efficient. To meet these requirements, we propose the flexible DC energy router (FeDER), a modular and scalable power management unit for interconnected lunar DC microgrids. The FeDER integrates local energy storage and addresses various microgrid power management needs such as fault management, stability enhancement, power flow regulation, and power quality improvement. The lunar DC microgrids' design, protection, and control are achieved using a three-layered approach: (1) graph theory, (2) energy management system, and (3) smart resistor control. The lunar power grid architecture is introduced and the FeDER stability enhancement is implemented in the OPAL-RT platform.
Technical Paper

Steady State Characterization of Arcing in 540 V dc Distribution Systems

2017-09-19
2017-01-2035
As applications in aerospace, transportation and data centers are faced with increased electric power consumption, their dc operating voltages have increased to reduce cable weight and to improve efficiency. Electric arcs in these systems still cause dangerous fault conditions and have garnered more attention in recent years. Arcs can be classified as either low impedance or high impedance arcs and both can cause insulation damage and fires. Low impedance arcs release lots of energy when high voltage becomes nearly shorted to ground. High impedance arcs can occur when two current-carrying electrodes are separated, either by vibration of a loose connection or by cables snapping. The high impedance arc decreases load current due to a higher equivalent load impedance seen by the source. This complicates the differentiation of a high impedance arc fault from normal operation.
Technical Paper

Charging Strategy Studies for PHEV Batteries based on Power Loss Model

2010-04-12
2010-01-1238
This paper describes a new method to increase the efficiency of the battery charging process, η, which is defined as the ratio of the energy accumulated in the battery over the actual energy supplied to it. Through several simulation results, it has been found that such efficiency is a function of the current profile applied to the battery during the charging process; hence, plots describing the energy loss in the battery, time taken to achieve a desired level of charge, and power needed as a function of the charging current, are shown. In order to find the optimal charging current profile, the mathematical model of the energy loss in the battery is developed and the problem of finding the optimal current profile is formulated as an Optimal Control problem. A model based on a Lithium-Ion Battery commercially available for PHEV is used as the plant to be controlled.