Refine Your Search

Search Results

Author:
Viewing 1 to 16 of 16
Technical Paper

Study of Flashing Flows Entering Evacuated Sampling Cylinders for Oil Circulation Rate Measurement in an Automotive Air Conditioning System

2023-04-11
2023-01-0140
The oil circulation rate (OCR) is a deciding factor for the performance of automotive air conditioning systems at both the system and component levels. OCR is defined as the percentage by mass of oil present in a representative sample of oil-refrigerant mixture drawn from the system at steady state. In recent years, many industries are opting for low-OCR compressors, and so the OCR values are getting smaller, making it even more important to be able to accurately measure the OCR in the system. All the different OCR measurement techniques rely on the ASHRAE Standard 41.4 for proper calibration. This standard describes OCR measurement using a sampling technique which involves connecting an evacuated sampling cylinder at the liquid line of the system at steady state to draw a sample containing the liquid mixture of refrigerant and oil. However, several factors such as orientation of sampling cylinder and valve opening speed can affect the OCR results.
Technical Paper

Oil Droplet vs. Film Flow at Discharge and Suction after Shutdown of Automotive Compressor

2023-04-11
2023-01-0141
The compressor oil is retained at different locations of the vapor compression system during operation. After shutdown, retained oil absorbs the vapor refrigerant and mixes with the liquid refrigerant gradually. Oil retention can largely affect the heat transfer and cause insufficient oil return. In this paper, the liquid mixture behaviors at the compressor suction and discharge are observed by flow visualization. Liquid mixture property variations are estimated by existing models according to the temperature and pressure variations. At the suction, the vapor refrigerant solubility with oil rapidly increases due to the pressure increase. The viscosity and surface tension decrease quickly with temperature and refrigerant mass fraction increase in the liquid layer. Flow visualization shows that the mixture film breaks from the top of the tube wall and flows down. The oil-refrigerant mixture accumulates at the bottom of the tube within seconds. The liquid level increases then decreases.
Technical Paper

Transient Oil Migration and Flow Behavior during Automotive Compressor Startup

2023-04-11
2023-01-0142
Oil migration has a great impact on vapor compression systems, especially for automobile air conditioning systems which require frequent on-off cycling without sufficient oil management inside the compressor. Excessive amounts of oil retained in the system and lack of oil returned to the compressor can cause low system efficiency and potential compressor failure. This paper explores and quantifies the transient effects in oil migration and property changes at the compressor suction and the discharge. Oil flow behavior and oil migration are quantified and analyzed by the high-speed camera recording and optical method at the compressor discharge and the liquid line under different compressor startup speeds and on-off frequencies. The flow under cold and warm startup conditions is studied and compared. The oil-refrigerant mixture flow at the suction and discharge during cold startup transitions from two-phase flow to vapor refrigerant flow and oil annular mist flow.
Journal Article

Measurements of Oil Circulation Rate using Flow-through and Evacuated Type Sampling Cylinders for an Automotive Air Conditioning System

2023-04-11
2023-01-0138
In automotive air conditioning systems, the oil circulation rate (OCR) is known to affect performance at both the component and system levels. The OCR is the ratio of the mass of the oil in a representative sample of oil-refrigerant mixture from the system to the total mass of the sample taken during steady state operation. With the general industry trend towards low-OCR compressors, the OCR values of interest are getting smaller, and it is becoming increasingly important to acquire an accurate knowledge of OCR for proper system optimization. While there are different OCR measurement techniques available, they all require accurate calibration which is done using the ASHRAE Standard 41.4. The standard describes a sampling technique using an evacuated sampling cylinder with a dead end to draw a sample of oil-refrigerant mixture from the system liquid line.
Technical Paper

Development of a New Ejector Performance Map for Design of an Automotive Air Conditioning System

2020-04-14
2020-01-1244
Ejector as a work recovery device offers potential for developing energy efficient heating and cooling systems based on vapor compression technology. For applications like automobile air conditioning, the operating conditions vary significantly which can lead to considerable performance degradation when the system is operated in off-design conditions. Therefore, system designing warrants development of accurate ejector performance models for a wide range of operating conditions. In this paper, a novel methodology for ejector performance maps is proposed using ejector efficiency as performance parameter and volumetric entrainment ratio as characterization parameter. The proposed performance map is developed after conducting experiments to find appropriate performance representation where ejector driven flow can be characterized using ejector motive flow. The developed performance map can predict ejector pressure lift within an accuracy of 20% using an iterative solver.
Technical Paper

Sound Evaluation of Flow-Induced Noise with Simultaneous Measurement of Flow Regimes at TXV Inlet of Automotive Evaporators

2020-04-14
2020-01-1255
In the air conditioning system, flow-induced noise is very disturbing, including the noise generated in the expansion device and the heat exchangers. In the past few decades, most researches related to flow-induced noise focused on the relationship between the flow regimes near the expansion device and the amplitude of flow-induced noise when the measurements are not synched. In this paper, an experimental approach is used to explore the simultaneous relationships between flow-induced noise characteristics and flow regimes at the inlet of TXV of evaporators used in automobiles. A pumped R134a loop with microphones and transparent visualization sections is used to simulate the vapor compression system. Also, the paper evaluates the severity of flow-induced noise from not only the amplitude of noise but also the frequency of noise with a parameter called psychoacoustic annoyance (PA).
Journal Article

Visualization Study of the Relationship between the Orientation of Tube and the Flow Regimes Near the Expansion Valve

2020-04-14
2020-01-1256
Several types of noise exist in automobiles. The flow-induced noise in the expansion device can be very disturbing since the expansion device is located near the occupants. In many studies, the flow-induced noise is found to be mitigated when the orientation of the tube is changed. However, no study explores the reason why flow-induced noise changes when the orientation of the tube is changed. The flow-induced noise varies along with the flow regimes near the expansion devices. In this paper, an experimental based research is used to study how the tube orientation changes the flow regimes under the same operating conditions. A pumped R134a system with transparent tubes (1/4-inch ID) is used to visualize the flow regimes near the manual expansion valve. The transparent tube is a continuous connection of horizontal tubes, 45° inclined tubes, and vertical tubes.
Technical Paper

Application of Vortex Control to an Automotive Transcritical R744 Ejector Cycle

2018-04-03
2018-01-0060
Expansion work recovery by two-phase ejector is known to be beneficial to vapor compression cycle performance. However, one of the biggest challenges with ejector vapor compression cycles is that the ejector cycle performance is sensitive to working condition changes which are common in automotive applications. Different working conditions require different ejector geometries to achieve maximum performance. Slightly different geometries may result in substantially different COPs under the same conditions. The ejector motive nozzle throat diameter (motive nozzle restrictiveness) is one of the key parameters that can significantly affect ejector cycle COP. This paper presents the experimental results of the application of a new two-phase nozzle restrictiveness control mechanism to an automotive transcritical R744 ejector cycle.
Technical Paper

Oil Circulation Rate in Ejector Cooling Cycles

2018-04-03
2018-01-0077
In this study, the influence of compressor speed, ejector motive nozzle needle position and evaporator inlet metering valve opening on the oil circulation rates (OCRs) of an automotive R744 transcritical standard ejector cycle was experimentally investigated. Significantly higher OCR (~10%) was observed at the evaporator inlet of the ejector cycle than at the high pressure side. It has been observed that evaporator OCR was increased with increasing compressor speed. When the motive nozzle needle moved towards the nozzle throat, both compressor discharge flow rate and evaporator OCR were observed to be significantly lowered. As the evaporator inlet metering valve opening was adjusted, the compressor mass flow rate did not vary significantly while the evaporator mass flow rate decreased with decreasing metering valve opening. The evaporator OCR decreased from 6.5% to 2.2% as the metering valve opening varied from 86% to 27%.
Technical Paper

Implementation of Reinforcement Learning on Air Source Heat Pump Defrost Control for Full Electric Vehicles

2018-04-03
2018-01-1193
Air source heat pumps as the heating system for full electric vehicles are drawing more and more attention in recent years. Despite the high energy efficiency, frost accumulation on the heat pump evaporator is one of the major challenges associated with air source heat pumps. The evaporator needs to be actively defrosted periodically and heat pump heating will be interrupted during defrosting process. Proper defrost control is needed to obtain high average heat pump energy efficiency. In this paper, a new method for generating air source heat pump defrost control policy using reinforcement learning is introduced. This model-free method has several advantages. It can automatically generate optimal defrost control policy instead of requiring manually determination of the control policy parameters and logics.
Journal Article

Influence of Nozzle Divergent Part Length and Throat Diameter on Vortex Control of Initially Subcooled Flashing Flow

2017-03-28
2017-01-0165
Expansion work recovery by two-phase ejector is known to be beneficial to vapor compression cycle performance. However, one of the biggest challenges with ejector vapor compression cycle is that the ejector cycle performance is sensitive to working condition changes which are common in many applications, including automotive AC systems. Different working conditions require different ejector geometries to achieve maximum performance. Slightly different geometries may result in substantially different COPs under the same conditions. Ejector motive nozzle throat diameter (motive nozzle restrictiveness) is one of the key parameters that can significantly affect COP. This paper presents the experimental investigation of a new motive nozzle restrictiveness control mechanism for two-phase ejectors used in vapor compression cycles, which has the advantages of being simple, potentially less costly and less vulnerable to clogging.
Technical Paper

Vortex Tube Heat Booster to Improve Performance of Heat Driven Cooling Cycles for Automotive Applications

2016-04-05
2016-01-0245
Increasing energy costs justify research on how to improve utilization of low-grade energy that is abundantly available as waste heat from many thermodynamic processes such as internal combustion engine cycles. One option is to directly generate cooling through absorption/adsorption or vapor jet ejector cycles. As in the case of power generation cycles, cooling cycle efficiencies would increase if the heat input were available at higher temperature. This paper assesses the feasibility of a novel idea that uses a vortex tube to increase the available temperature levels of low-grade heat sources. The desired temperature increase is achieved by sending a stream of vapor that was heated by the waste heat source through a vortex tube, which further elevates the temperature used in a heat driven ejector cooling cycle.
Journal Article

A New Control Mechanism for Two-Phase Ejector in Vapor Compression Cycles for Automotive Applications Using Adjustable Motive Nozzle Inlet Swirl

2016-04-05
2016-01-0243
Expansion work recovery by two-phase ejector is known to be beneficial to vapor compression cycle performance. However, one of the biggest challenges with ejector vapor compression cycles is that the ejector cycle performance is sensitive to working condition changes which are common in automotive applications. Different working conditions require different ejector geometries to achieve maximum performance. Slightly different geometries may result in substantially different COPs under the same conditions. The ejector motive nozzle throat diameter (motive nozzle restrictiveness) is one of the key parameters that can significantly affect ejector cycle COP. This paper presents a new two-phase nozzle restrictiveness control mechanism which is possibly applicable to two-phase ejectors used in vapor compression cycles.
Technical Paper

Numerical Investigation of the Effect of Microchannel Evaporator Design on the Performance of Two-Phase Ejector Automotive Air Conditioning Cycles

2015-04-14
2015-01-0362
Much attention has been given in recent years to the use of two-phase ejectors and particularly to the performance of the standard ejector cycle with a liquid-vapor separator. However, this cycle may not be the best choice for automotive applications due to the large size required by an efficient separator as well as the cycle's performance at conditions of lower ejector potential. A limited amount of recent research has focused on alternate two-phase ejector cycles that may be better suited for automotive applications. One of these cycles, using the ejector to allow for evaporation at two different temperatures and eliminating the need for a separator, will be the subject of investigation in this paper. Previous investigations of this cycle have been mainly theoretical or experimental; this paper aims to provide a numerical analysis of the effect of evaporator design on the performance of the ejector cycles.
Technical Paper

Comparison of CO2 and R134a Two-Phase Ejector Performance for Use in Automotive Air Conditioning Applications

2014-04-01
2014-01-0689
Two-phase ejectors are devices capable of recovering the expansion power that is lost by the throttling process in air conditioning cycles, resulting in improved system performance. High-pressure fluids such as CO2 have received the majority of attention in two-phase ejector studies in recent years due to the fluid's high throttling loss and high potential for improvement. However, low-pressure working fluids such as R134a, commonly used in automotive applications, have received considerably less attention owing to their lower recovery potential. While the two fluids have very different properties, both offer the potential for noticeable COP improvement with ejector cycles. Thus, understanding the operation and performance of ejectors with both fluids can be important to the design of ejector air conditioning cycles. This paper compares available experimental data for the performance of two-phase ejectors using CO2 and R134a.
Technical Paper

Experimental and Analytical Investigation of Two-Phase Ejector Air-Conditioning Cycles Using Low-Pressure Refrigerants R134a and R1234yf

2013-04-08
2013-01-1495
Two-phase ejectors have received increased attention in recent years because of their ability to improve the performance of automotive air-conditioning cycles by means of expansion work recovery. Much attention in recent years has been given to how high-pressure fluids, such as carbon dioxide, perform with ejector cycles; high-pressure fluids tend to have higher throttling loss, making them more attractive for expansion work recovery cycles, such as the two-phase ejector cycle. However, low-pressure fluids, such as those commonly used in automotive air-conditioning applications, tend to offer significantly lower work recovery potential. Nonetheless, the limited previous work on low-pressure refrigerants in ejector systems has shown that there is some improvement potential when using these fluids with ejector cycles.
X