Refine Your Search

Search Results

Author:
Viewing 1 to 19 of 19
Technical Paper

Application of CAEBAT Full Field Approach for a Liquid-Cooled Automotive Battery Pack

2016-04-05
2016-01-1217
The Computer-Aided Engineering of Automotive Batteries (CAEBAT) Phase 1 project is a U.S. Department of Energy-funded, multi-year project which is aimed at developing a complete CAE tool set for the automotive battery pack design. This paper reports the application of the full field approach of the CAEBAT which is developed by the General Motors-led industry team, for a 24-cell liquid-cooled prototype battery pack. It also summarizes the verification of the approach by comparing the simulation results with the measurement data. The simulation results using the Full Field Approach are found to have a very good agreement with the measurement data.
Technical Paper

A CFD Study of Drag Reduction Devices for a Full Size Production Pickup Truck

2015-04-14
2015-01-1541
Various drag reduction strategies have been applied to a full size production pickup truck to evaluate their effectiveness by using Computational Fluid Dynamics (CFD). The drag reduction devices evaluated in this study were placed at the rear end of the truck bed and the tailgate. Three types of devices were evaluated: (1) boat tail-like extended plates attached to the tailgate; (2) mid-plate attached to the mid-section of the tailgate and; (3) flat plates partially covering the truck bed. The effect of drag reduction by various combinations of these three devices are presented in this paper. Twenty-four configurations were evaluated in the study with the best achievable drag reduction of around 21 counts (ΔCd = 0.021). A detailed breakdown of the pressure differentials at the base of the truck is provided in order to understand the flow mechanism for the drag reductions.
Technical Paper

Energy Efficiency Impact of Localized Cooling/Heating for Electric Vehicle

2015-04-14
2015-01-0352
The present paper reports on a study of the HVAC energy usage for an EREV (extended range electric vehicle) implementation of a localized cooling/heating system. Components in the localized system use thermoelectric (TE) devices to target the occupant's chest, face, lap and foot areas. A novel contact TE seat was integrated into the system. Human subject comfort rides and a thermal manikin in the tunnel were used to establish equivalent comfort for the baseline and localized system. The tunnel test results indicate that, with the localized system, HVAC energy savings of 37% are achieved for cooling conditions (ambient conditions greater than 10 °C) and 38% for heating conditions (ambient conditions less than 10 °C), respectively based on an annualized ambient and vehicle occupancy weighted method. The driving range extension for an electric vehicle was also estimated based on the HVAC energy saving.
Journal Article

Localized Cooling for Human Comfort

2014-04-01
2014-01-0686
Traditional vehicle air conditioning systems condition the entire cabin to a comfortable range of temperature and humidity regardless of the number of passengers in the vehicle. The A/C system is designed to have enough capacity to provide comfort for transient periods when cooling down a soaked car. Similarly for heating, the entire cabin is typically warmed up to achieve comfort. Localized heating and cooling, on the other hand, focuses on keeping the passenger comfortable by forming a micro climate around the passenger. This is more energy efficient since the system only needs to cool the person instead of the entire cabin space and cabin thermal mass. It also provides accelerated comfort for the passenger during the cooling down periods of soaked cars. Additionally, the system adapts to the number of passengers in the car, so as to not purposely condition areas that are not occupied.
Technical Paper

Energy Efficiency Impact of Localized Cooling

2014-04-01
2014-01-0695
Traditional vehicle air conditioning systems are designed to cool the entire cabin to provide passenger comfort. Localized cooling, on the other hand, focuses on keeping the passenger comfortable by creating a micro climate around the passenger. Such a system also easily adapts to the number of passengers in the car and enables zonal control. The net impact of the localized cooling is that equivalent comfort can be achieved at reduced HVAC energy consumption rate. The present paper reports on a vehicle implementation of localized cooling using Thermoelectric Devices and the resulting energy saving.
Journal Article

Numerical Investigation of Buoyancy-Driven Flow in a Simplified Underhood with Open Enclosure

2013-04-08
2013-01-0842
Numerical results are presented for simulating buoyancy driven flow in a simplified full-scale underhood with open enclosure in automobile. The flow condition is set up in such a way that it mimics the underhood soak condition, when the vehicle is parked in a windbreak with power shut-down after enduring high thermal loads due to performing a sequence of operating conditions, such as highway driving and trailer-grade loads in a hot ambient environment. The experimental underhood geometry, although simplified, consists of the essential components in a typical automobile underhood undergoing the buoyancy-driven flow condition. It includes an open enclosure which has openings to the surrounding environment from the ground and through the top hood gap, an engine block and two exhaust cylinders mounted along the sides of the engine block. The calculated temperature and velocity were compared with the measured data at different locations near and away from the hot exhaust plumes.
Journal Article

Energy Efficient HVAC System with Spot Cooling in an Automobile - Design and CFD Analysis

2012-04-16
2012-01-0641
Spot, or distributed, cooling and heating is an energy efficient way of delivering comfort to an occupant in the car. This paper describes an approach to distributed cooling in the vehicle. A two passenger CFD model of an SUV cabin was developed to obtain the solar and convective thermal loads on the vehicle, characterize the interior thermal environment and accurately evaluate the fluid-thermal environment around the occupants. The present paper focuses on the design and CFD analysis of the energy efficient HVAC system with spot cooling. The CFD model was validated with wind tunnel data for its overall accuracy. A baseline system with conventional HVAC air was first analyzed at mid and high ambient conditions. The airflow and cooling delivered to the driver and the passenger was calculated. Subsequently, spot cooling was analyzed in conjunction with a much lower conventional HVAC airflow.
Technical Paper

Development of a Virtual Thermal Manikin to Predict Thermal Sensation in Automobiles

2012-04-16
2012-01-0315
In today's highly competitive marketplace and ever-shrinking vehicle development cycle, automotive HVAC engineers are constantly challenged to develop systems that deliver adequate thermal comfort at lower cost and higher fuel-efficiency. However, in the absence of a reliable predictive tool that is capable of quantifying thermal comfort early in the vehicle development program, OEMs employ expensive and time-consuming human subject test rides to assess HVAC system's performance. In order to address this issue, a Computational Fluid Dynamics (CFD) model of a virtual thermal manikin in a passenger cabin is developed in this study. The model is capable of providing thermal sensations, as experienced by humans, under any arbitrary thermal environment. Additionally, the model can provide sensitivity of various critical parameters, such as solar load, A/C discharge outlet air flow-rate and temperature, A/C outlet locations, various HVAC modes etc., to thermal sensation.
Technical Paper

Thermal Comfort Prediction and Validation in a Realistic Vehicle Thermal Environment

2012-04-16
2012-01-0645
The focus of this study is to validate the predictive capability of a recently developed physiology based thermal comfort modeling tool in a realistic thermal environment of a vehicle passenger compartment. Human subject test data for thermal sensation and comfort was obtained in a climatic wind tunnel for a cross-over vehicle in a relatively warm thermal environment including solar load. A CFD/thermal model that simulates the vehicle operating conditions in the tunnel, is used to provide the necessary inputs required by the stand-alone thermal comfort tool. Comparison of the local and the overall thermal sensation and comfort levels between the human subject test and the tool's predictions shows a reasonably good agreement. The next step is to use this modeling technique in designing and developing energy-efficient HVAC systems without compromising thermal comfort of the vehicle occupants.
Journal Article

Micro-Cooling/Heating Strategy for Energy Efficient HVAC System

2011-04-12
2011-01-0644
Energy efficient HVAC system is becoming increasingly important as higher Corporate Average Fuel Economy (CAFE) standards are required for future vehicle products. The present study is a preliminary attempt at designing energy efficient HVAC system by introducing localized heating/cooling concepts without compromising occupant thermal comfort. In order to achieve this goal of reduced energy consumption while maintaining thermal comfort it is imperative that we use an analytical model capable of predicting thermal comfort with reasonable accuracy in a non-homogenous enclosed thermal environment such as a vehicle's passenger cabin. This study will primarily focus on two aspects: (a) energy efficiency improvements in an HVAC system through micro-cooling/heating strategies and (b) validation of an analytical approach developed in GM that would support the above effort.
Journal Article

Assessment of Various Environmental Thermal Loads on Passenger Thermal Comfort

2010-04-12
2010-01-1205
Virtual simulation of passenger compartment climatic conditions is becoming increasingly important as a complement to the wind tunnel and field testing to achieve improved thermal comfort while reducing the vehicle development time and cost. The vehicle cabin is subjected to various thermal environments. At the same time many of the design parameters are dependent on each other and the relationship among them is quite complex. Therefore, an experimental parametric study is very time consuming. The present 3-D RadTherm analysis coupled with the 3-D CFD flow field analysis takes into account the geometrical configuration of the passenger compartment which includes glazing surfaces and pertinent physical and thermal properties of the enclosure with particular emphasis on the glass properties. Virtual Thermal Comfort Engineering (VTCE) is a process that takes into account the cabin thermal environment coupled with a human physiology model.
Journal Article

Wind Noise Measurements for Automotive Mirrors

2009-04-20
2009-01-0184
In order to understand the flow and wind noise characteristics generated by the outside rearview (OSRV) mirror, a series of wind noise measurements for two production mirrors was conducted at the GM Aerodynamics Lab (GMAL) wind tunnel. These measurements included the time-averaged static pressures, surface noise sources, and far field propagation noise. The data obtained in this investigation will be used for future CFD numerical validations. The two mirrors chosen for the test are the GMT360 (a truck mirror) and the GMX320 (a sedan mirror). The test mirror was mounted on an elevated table which was specially designed for the current project to avoid any significant flow boundary layer buildup on the wind tunnel floor. The test conditions reported in this paper include four inlet speeds of 30, 50, 70 and 90 mph at 0 yaw angle. To record the wind noise sources, nine surface flush-mount microphones were used.
Technical Paper

Assessment of Various Environmental Thermal Loads on Passenger Compartment Soak and Cool-down Analyses

2009-04-20
2009-01-1148
Energy efficient HVAC system is becoming increasingly important as the higher Corporate Average Fuel Economy (CAFE) standards are required for future vehicle products. The present study is a preliminary investigation which addresses an energy efficient HVAC system without compromising occupant thermal comfort. The vehicle cabin is subjected to various thermal environments. Thermal analysis of a passenger compartment involves not only the geometric complexity but also strong interactions between airflows and three modes of heat transfer, namely, heat conduction, convection, and thermal radiation. The present full 3-D CFD analysis takes into account the geometrical configuration of the passenger compartment including glazing surfaces and pertinent physical and thermal properties of the enclosure with particular emphasis on glass properties. Many of the design parameters related with the climate control system are dependent on each other and the relationship among them is quite complex..
Technical Paper

Experimental Characterization of the Unsteady Flow Field behind Two outside Rear View Mirrors

2008-04-14
2008-01-0476
The unsteady flow fields behind two different automobile outside side rear view mirrors were examined experimentally in order to obtain a comprehensive data base for the validation of the ongoing computational investigation effort to predict the aero-acoustic noise due to the outside rear view mirrors. This study is part of a larger scheme to predict the aero-acoustic noise due to various external components in vehicles. To aid with the characterization of this complex flow field, mean and unsteady surface pressure measurements were undertaken in the wake of two mirror models. Velocity measurements with particle image velocimetry were also conducted to develop the mean velocity field of the wake. Two full-scale mirror models with distinctive geometrical features were investigated.
Technical Paper

The Immersed Boundary CFD Approach for Complex Aerodynamics Flow Predictions

2007-04-16
2007-01-0109
Standard CFD methods require a mesh that fits the boundaries of the computational domain. For a complex geometry the generation of such a grid is time-consuming and often requires modifications to the model geometry. This paper evaluates the Immersed Boundary (IB) approach which does not require a boundary-conforming mesh and thus would speed up the process of the grid generation. In the IB approach the CAD surfaces (in Stereo Lithography -STL- format) are used directly and this eliminates the surface meshing phase and also mitigates the process of the CAD cleanup. A volume mesh, consisting of regular, locally refined, hexahedrals is generated in the computational domain, including inside the body. The cells are then classified as fluid, solid and interface cells using a simple ray-tracing scheme. Interface cells, correspond to regions that are partially fluid and are intersected by the boundary surfaces.
Technical Paper

Exterior Water Management Using a Custom Euler-Lagrange Simulation Approach

2007-04-16
2007-01-0101
The reduction of hardware vehicle models during development drives the necessity to transfer most hardware tests to VR Simulation. Exterior water management is one of the topics, where complex physics meet everyday situations. A vehicle contamination test conducted in a wind tunnel is selected to be transferred to numerical simulation. The method of choice is the Euler-Lagrange approach with modeled ‘liquid’ wall particles. A new wall film model has been developed in the present study to include the observed liquid properties in physical test. This model takes the local wetting conditions into account and constitutes a reformulation of the local force balance of the wall liquid. Also the wall film separation model has been refined and improved. With this new approach, the gas/liquid, liquid/solid and liquid/liquid interaction has been remodeled.
Technical Paper

Investigation of the Buoyancy Driven Flow in a Simplified Underhood - Part II, Numerical Study

2006-04-03
2006-01-1607
This paper describes the numerical results for a simplified underhood buoyancy driven flow. The simplified underhood geometry consists of an enclosure, an engine block and two exhaust cylinders mounted along the sides of the engine block. The flow condition is set up in such a way that it mimics the buoyancy driven flow condition in the underhood environment when the vehicle is parked in a windbreak with the engine shut down. The experimental measurements for temperature and velocity of the same configuration were documented in the Part I of the same title. Present study focuses on the numerical issues of calculating temperature and flow field for the same flow configuration. The predicted temperature and velocity were compared with the available measured data. The mesh sizes, mesh type and the orders of spatial and temporal accuracy of the numerical setup are discussed.
Technical Paper

Investigation of the Buoyancy Driven Flow in a Simplified Underhood-Part I, PIV and Temperature Measurements

2006-04-03
2006-01-1608
The results of thermal and flow studies for a ¼ scale model of an engine compartment are presented here. Using PIV and thermocouples, the mid-plane flow velocity and temperature of the buoyant underhood flow with engine block average surface temperature of 127°C and exhaust heaters (surface temperature ∼ 600°C) were measured. Thermocouples were also used to measure the steady-state temperature of the engine block surface and the enclosure outside and inside walls. The airflow in the engine compartment is steady, laminar and three dimensional as predicted by the Grashof and Reynolds numbers calculated for different simple geometries comprising the engine block and its exhausts. Three dominant vortices are found to exist at the top corners of the engine compartment. Thermal measurements on the engine block and enclosure surfaces support the temperature gradients expected given the specified geometry and boundary conditions.
Technical Paper

Aeroacoustics of an Automotive A-Pillar Raingutter: A Numerical Study with the Ffowcs-Williams Hawkings Method

2005-05-16
2005-01-2492
A numerical simulation of the flow structure around an idealized automotive A-pillar rain-gutter and the sound radiated from it is reported. The idealized rain-gutter is an infinitesimally thin backward facing elbow mounted on a flat plate. It is kept in a virtual wind-tunnel with rectangular cross-section. The transient flow structure around the rain-gutter is described and time-averaged pressure distribution along the base plate is provided. Time-varying static pressure was recorded on every grid point on the base-plate as well as the rain-gutter surfaces and used to calculate sound pressure signal at a microphone held above the rain-gutter using the Ffowcs-Williams-Hawkings (FWH) integral method was used for calculating sound propagation. Both the transient flow simulation as well as the FWH sound calculation were performed using the commercial CFD code FLUENT6.1.22.
X