Refine Your Search

Search Results

Author:
Viewing 1 to 2 of 2
Technical Paper

Performance Evaluation of Automotive HVAC System with the Use of Liquid Cooled Condenser

2014-04-01
2014-01-0681
Air-cooled fin and tube heat exchangers are used as a condenser in the conventional automotive Heating Ventilation & Air-Conditioning (HVAC) systems. In this study, the use of liquid cooled plate heat exchanger as a condenser in the automotive HVAC systems has been investigated. In the proposed configuration, the cabin heat absorbed by the refrigerant in HVAC system is rejected to the coolant through a liquid cooled condenser and then to the ambient air through a low temperature radiator. Hence, the proposed configuration combines heat rejection from HVAC system with a low temperature radiator circuit of power train cooling. Mixture of Ethylene glycol & Water (coolant), which is used in power train cooling system, is used as secondary fluid in the condenser.
Technical Paper

Simulation of a Vehicle Refrigeration Cycle with Dymola/Modelica

2005-04-11
2005-01-1899
Development times in the automotive industry are becoming increasingly shorter. For this reason, design decisions based on simulation results must be made at an early development stage. The dynamic simulation of an automotive refrigeration cycle with Dymola/Modelica as part of the design process will be described in the following paper. The component supplier's expertise as well as the automotive manufacturer's knowledge of vehicle parameters in one simulation platform will also be discussed.
X