Refine Your Search

Search Results

Viewing 1 to 7 of 7
Journal Article

Development of New Hydrogen Fueling Method for Fuel Cell Motorcycle

2017-03-28
2017-01-1184
A new hydrogen fueling protocol named MC Formula Moto was developed for fuel cell motorcycles (FCM) with a smaller hydrogen storage capacity than those of light duty FC vehicles (FCV) currently covered in the SAE J2601 standard (over than 2kg storage). Building on the MC Formula based protocol from the 2016 SAE J2601 standard, numerous new techniques were developed and tested to accommodate the smaller storage capacity: an initial pressure estimation using the connection pulse, a fueling time counter which begins the main fueling time prior to the connection pulse, a pressure ramp rate fallback control, and other techniques. The MC Formula Moto fueling protocol has the potential to be implemented at current hydrogen stations intended for fueling of FCVs using protocols such as SAE J2601. This will allow FCMs to use the existing and rapidly growing hydrogen infrastructure, precluding the need for exclusive dispensers or stations.
Journal Article

Field Validation of the MC Default Fill Hydrogen Fueling Protocol

2015-04-14
2015-01-1177
Appendix H of the SAE J2601 standard defines a development hydrogen fueling protocol named the MC Default Fill, which builds upon the foundation of the table based protocol, utilizing the same assumptions, boundary conditions, and process limits as the current standard. The MC Default Fill facilitates the following beyond the table based protocol: 1) the potential to provide faster, more consistent fueling times for fuel cell electric vehicle customers, and 2) the ability to continuously and dynamically adjust to a wide range of dispenser fuel delivery temperatures, allowing for more flexibility in station design. Computer simulations and laboratory bench tests were previously conducted and documented, validating the function and operation of the protocol.
Journal Article

Validation and Sensitivity Studies for SAE J2601, the Light Duty Vehicle Hydrogen Fueling Standard

2014-04-01
2014-01-1990
The worldwide automotive industry is currently preparing for a market introduction of hydrogen-fueled powertrains. These powertrains in fuel cell electric vehicles (FCEVs) offer many advantages: high efficiency, zero tailpipe emissions, reduced greenhouse gas footprint, and use of domestic and renewable energy sources. To realize these benefits, hydrogen vehicles must be competitive with conventional vehicles with regards to fueling time and vehicle range. A key to maximizing the vehicle's driving range is to ensure that the fueling process achieves a complete fill to the rated Compressed Hydrogen Storage System (CHSS) capacity. An optimal process will safely transfer the maximum amount of hydrogen to the vehicle in the shortest amount of time, while staying within the prescribed pressure, temperature, and density limits. The SAE J2601 light duty vehicle fueling standard has been developed to meet these performance objectives under all practical conditions.
Technical Paper

Application of MC Method-Based H2 Fueling

2012-04-16
2012-01-1223
To address challenges related to refueling with compressed hydrogen, a simple, analytical method has been developed that allows a hydrogen station to directly and accurately calculate an end-of-fill temperature in a hydrogen tank and thereby maximize the fill quantity and minimize the refueling time. This is referred to as the MC Fueling Method, where MC represents total heat capacity. The MC Method incorporates a set of thermodynamic parameters for the tank system that are used by the station in a simple analytical equation along with measured values of dispensed hydrogen temperature and pressure at the station. These parameters can be communicated to the hydrogen station either directly from the vehicle or from a database that is accessible by the station. Because the MC Method is based on direct measurements of actual thermodynamic conditions at the station, and quantified thermodynamic behavior of the tank system, highly accurate tank filling results can be achieved.
Technical Paper

Investigating the Optimum Practical Hydrogen Working Pressure for Gaseous Hydrogen Fueled Vehicles

2010-04-12
2010-01-0854
Today's fuel cell powered vehicles typically utilize compressed hydrogen storage systems with a nominal working pressure of either 35MPa or 70Mpa. This coexistence of working pressures has, in a large part, developed in isolation, in that automakers have primarily considered vehicle side issues when choosing the storage system pressure. This study looks at hydrogen fueling from a holistic perspective by considering both vehicle side and station side issues with the goal to determine an optimum hydrogen working pressure. The approach utilized is to first conduct a data driven study of vehicle fueling at different working pressures and ambient temperatures to determine the vehicle and thermodynamic considerations of hydrogen fueling. This data is then contrasted with the hydrogen station hardware required to perform fueling at these temperatures and pressures.
Technical Paper

Development of a Hydrogen Flow Meter With High Accuracy at Low Flow Rates to Measure Fuel Consumption for Fuel Cell Vehicles

2009-04-20
2009-01-1007
With the increasing prevalence of fuel cell vehicles, hydrogen consumption during fuel economy certification needs to be measured in an accurate and convenient manner. Typically, consumption is measured by weighing hydrogen cylinders before and after testing and calculating the amount of depleted hydrogen by the difference in weight. This method is theoretically highly accurate but time-consuming. This paper describes a new method developed to measure hydrogen consumption using a flow meter system. With a flow meter input pressure of 2MPa, and a minimum flow rate of 4NL/min, this new system achieves a level of error that is within 0.5% of the weight measurement method, but is far simpler and reduces the measuring time by approximately 130 minutes.
Technical Paper

Gaseous Hydrogen Station Test Apparatus: Verification of Hydrogen Dispenser Performance Utilizing Vehicle Representative Test Cylinders

2005-04-11
2005-01-0002
The paper includes the development steps used in creating a station test apparatus (STA) and a description of the apparatus design. The purpose of this device is to simulate hydrogen vehicle conditions for the verification of gaseous hydrogen refueling station dispenser performance targets and hydrogen quality. This is done at the refueling station/vehicle interface (i.e. the refueling nozzle.) In addition, the device is to serve as a means for testing and developing future advanced fueling algorithms and protocols. The device is to be outfitted with vehicle representative container cylinders and sensors located inside and outside the apparatus to monitor refueling rate, ambient and internal gas temperature, pressure and weight of fuel transferred. Data is to be recorded during refueling and graphed automatically.