Refine Your Search

Search Results

Author:
Viewing 1 to 7 of 7
Technical Paper

Determination of Impact Responses of ES-2re and SID-IIs - Part III: Development of Transfer Functions

2018-04-03
2018-01-1444
An understanding of stiffness characteristics of different body regions, such as thorax, abdomen and pelvis of ES-2re and SID-IIs dummies under controlled laboratory test conditions is essential for development of both compatible performance targets for countermeasures and occupant protection strategies to meet the recently updated FMVSS214, LINCAP and IIHS Dynamic Side Impact Test requirements. The primary purpose of this study is to determine the transfer functions between the ES-2re and SID-IIs dummies for different body regions under identical test conditions using flat rigid wall sled tests. The experimental set-up consists of a flat rigid wall with five instrumented load-wall plates aligned with dummy’s shoulder, thorax, abdomen, pelvis and femur/knee impacting a stationary dummy seated on a rigid low friction seat at a pre-determined velocity.
Technical Paper

Determination of Impact Responses of ES-2re and SID-IIs – Part II: SID-IIs

2018-04-03
2018-01-1448
The main purpose of this study was to determine the impact responses of the different body regions (shoulder, thorax, abdomen and pelvis/leg) of the ES-2re and SID-IIs dummies using rigid wall impacts under different initial test conditions. The experimental set-up consisted of a flat rigid wall with five instrumented load-wall plates aligned with dummy’s shoulder, thorax, abdomen, pelvis and knee impacting a stationary dummy seated on a rigid seat at a pre-determined velocity. The relative location and orientation of the load-wall plates was adjusted relative to the body regions of the ES-2re and SID-IIs dummies respectively.
Technical Paper

Determination of Impact Responses of ES-2re and SID-IIs - Part I: ES-2re

2018-04-03
2018-01-1449
The main purpose of this study was to determine the impact responses of the different body regions (shoulder, thorax, abdomen and pelvis/leg) of the ES-2re and SID-IIs dummies using rigid wall impacts under different initial test conditions. The experimental set-up consisted of a flat rigid wall with five instrumented load-wall plates aligned with dummy’s shoulder, thorax, abdomen, pelvis and knee impacting a stationary dummy seated on a rigid seat at a pre-determined velocity. The relative location and orientation of the load-wall plates was adjusted relative to the body regions of the ES-2re and SID-IIs dummies respectively.
Technical Paper

Effects of Sinusoidal Whole Body Vibration Frequency on Drivers' Muscle Responses

2015-04-14
2015-01-1396
Low back pain has a higher prevalence among drivers who have long term history of vehicle operations. Vehicle vibration has been considered to contribute to the onset of low back pain. However, the fundamental mechanism that relates vibration to low back pain is still not clear. Little is known about the relationship between vibration exposure, the biomechanical response, and the physiological responses of the seated human. The aim of this study was to determine the vibration frequency that causes the increase of muscle activity that can lead to muscle fatigue and low back pain. This study investigated the effects of various vibration frequencies on the lumbar and thoracic paraspinal muscle responses among 11 seated volunteers exposed to sinusoidal whole body vibration varying from 4Hz to 30Hz at 0.4 g of acceleration. The accelerations of the seat and the pelvis were recorded during various frequency of vibrations. Muscle activity was measured using electromyography (EMG).
Technical Paper

Lumbar Support Prominence and Vertical Position Measurement Methods in an Occupied Seat

2006-04-03
2006-01-1300
In the automotive seating industry measurements of lumbar support prominence and height are performed to assess their effects on occupant comfort. This project investigated measurement methods for lumbar support prominence and height in an occupied seat. Fifteen participants provided subjective responses of their perceived lumbar support prominence and height utilizing specifically developed visual analog scales. Also, pressure measurements were taken while the participants were seated. The recently developed H-point manikin II was utilized as a standardized sitter. Specifically, the lumbar support prominence (LSP) measure was used for the prominence measures. Pressure mat readings with the seated manikin was used for lumbar support height determination and prominence correlations. With both manikin and participants in the seat, the lumbar support was digitized through the rear of the seat.
Technical Paper

An Analysis of Traumatic Rupture of the Aorta in Side Impact Sled Tests

2005-04-11
2005-01-0304
Traumatic rupture of the aorta (TRA) is a leading cause of death in high velocity blunt trauma, particularly motor vehicle accidents. However, little is understood about the mechanisms of TRA and thus, the opportunities to prevent TRA in the motor vehicle environment are compromised. The objective of this study was to determine the relationship between impact response and TRA through analyses of data from cadaver tests that successfully produced TRA in lateral impacts. Seventeen Heidelberg-style side impact sled tests were conducted using unembalmed human cadavers. Three sled speeds were used: 6.7, 9.0, and 10.5 m/s. Three barrier configurations were used: rigid flat wall, rigid wall with a 152-mm offset toward the pelvis, and a flat wall with padding of varying stiffness. Multiple load and acceleration measurements were made on the barrier and cadaver. Potential injury parameters were evaluated and their relative predictive abilities were examined.
Technical Paper

Biofidelity and Injury Assessment in Eurosid I and Biosid

1995-11-01
952731
Side impact pendulum tests were conducted on Eurosid I and Biosid to assess the biofidelity of the thorax, abdomen and pelvis, and determine injury tolerance levels. Each body region was impacted at 4.5, 6.7, and 9.4 m/s using test conditions which duplicate cadaver impacts with a 15 cm flat-circular 23.4 kg rigid mass. The cadaver database establishes human response and injury risk assessment in side impact. Both dummies showed better biofidelity when compared to the lowest-speed cadaver response corridor. At higher speeds, peak force was substantially higher. The average peak contact force was 1.56 times greater in Biosid and 2.19 times greater in Eurosid 1 than the average cadaver response. The Eurosid I abdomen had the most dissimilar response and lacks biofidelity. Overall, Biosid has better biofidelity than Eurosid I with an average 21% lower peak load and a closer match to the duration of cadaver impact responses for the three body regions.